期刊文献+

原子荧光光谱法测定二硫化硒洗剂中硒的含量 被引量:2

Content Determination of Se in Selenium Sulfide Lotion by Atomic Fluorescence Spectrometry
暂未订购
导出
摘要 目的建立测定二硫化硒洗剂中硒含量的原子荧光光谱法。方法利用HClO4-HNO3湿法消解,对二硫化硒洗剂中的硒进行原子荧光测定。结果硒在0~100μg.L-1范围内线性关系良好(r=0.9997),平均加样回收率为98.83%(RSD=0.5%,n=9)。结论所建立方法简单、结果准确,可有效控制二硫化硒洗剂的质量。 Objective To establish an atomic fluorescence spectrometry method to determine the content of Se in Selenium Sulfide Lotion.Methods The Se content in Selenium Sulfide Lotion was determined using atomic fluorescence spectrometry with wet digestion by HClO4-HNO3.Results The good linear range was determined as 0-100 μg·L-1 by atomic fluorescence spectrometry with a regression coefficient of 0.9997.The average recoveries was 98.83%(RSD=0.5%,n=9).Conclusion The method is simple,accurate and sensitive,suitable for quality control of Selenium Sulfide Lotion.
出处 《中国药事》 CAS 2012年第10期1105-1106,1118,共3页 Chinese Pharmaceutical Affairs
基金 邯郸市科学技术研究与发展计划项目(编号1123108161)
关键词 二硫化硒洗剂 含量测定 原子荧光光谱法 Selenium Sulfide Lotion content determination atomic fluorescence spectrophotom-etry Se
  • 相关文献

参考文献8

二级参考文献39

共引文献53

同被引文献16

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部