期刊文献+

电导率法快速检测食品细菌总数的研究 被引量:12

Study on Conductivity Method-a Rapid Detection Method for Food Total Aerobic Bacterial Count
在线阅读 下载PDF
导出
摘要 电导率法是最近发展起来的应用于微生物检验的一项电化学技术。本研究先建立了利用电导率法测定几种常见食品细菌总数的标准曲线,然后通过平行实验验证了电导率法快速检测食品细菌总数的重现性,再通过配对实验比较了电导率法与国标法测定结果符合率;经统计学卡方检验,结果 P>0.05,表明两种方法无显著性差异,结果符合率为92.7%;说明电导率法作为一种快速检测方法用于食品细菌总数的检验是可行的。 Conductivity method is a recently-developed electrochemistry technology in the microorganism detection. This study investigated the accuracy and reliability of the conductivity method on the rapid detection of food total aerobic bacterial count. At the first, three standard curves for three kinds of food were built up. And then, repeatability experiments and parallel experiments were conducted. Results indicted that there were no prominence difference between conductivity method and plate count method. The conductivity method can be used as a rapid detection method for total aerobic bacterial count in food.
出处 《现代食品科技》 EI CAS 北大核心 2012年第2期237-240,146,共5页 Modern Food Science and Technology
关键词 电导率法 细菌总数 快速检测 Conductivity method aerobic bacterial count rapid detection
  • 相关文献

参考文献9

二级参考文献30

  • 1韩振英.隐性乳房炎的简易诊断方法[J].河北畜牧兽医,1995,11(3):137-138. 被引量:2
  • 2戴金华 张长泉.以阻抗法快速检测食盒餐中之生菌数及大肠杆菌群[J].食品科学,1995,22(6):759-765.
  • 3[1]Walstra,P.,Jenness,R..1983.Dairy Chemistry and Physics[M].A Willey-Inter science Publication.
  • 4[8]Fernando,R.S.,Rindsig,R.B.and Spahr,S.L..Electrical conductivity of milk for detection of mastitis[J].J Dairy Sci,1982,65:659-664
  • 5[9]Fernando,R.S.Diagnosis of intramammary infection by the electrical conductivity of milk[D].University of Illinois,1983
  • 6[10]Nielen,M.,Schukken,Y.H.and Brand,A.et.al.Detection of subclinical mastitis from on-line milking parlor data[J].J.Dairy Sci,1995,78:1039-1049
  • 7SEVENSSON ULLA K. Starter culture characterization by conductanc emethods swedish dairies' asscciatiun[J] .Journal of dairy Science,1994, 77(12): 3 516-3 523.
  • 8COOMBS P, MARLATT F. Conductance microbiology in the dairy industry [ M ] . Food and Beverage Technology International USA,1989. 209 -211.
  • 9Coppola, K. and Firstenberg- Eden, R.Impedance based method for detection of spoilage organisa-ns in UHT low- acid foods[J]. Journal of food Science. 1998, 53:1521-1527.
  • 10Pugh S J, Griffiths J L, Arnott,M L and Gutteridge, C S. A complete protocol using conductance for rapid detection of salmonellas in confectionary materials[J]. Letters in Applied Microbiology.1998, 7: 23-27.