期刊文献+

闭管加热法测定游泳池中尿素含量 被引量:3

Determination of urea content in swimming pool water by closed tube heating method
原文传递
导出
摘要 目的建立实用、准确、快速的游泳池水中尿素检测方法。方法利用闭管加热直读,改变加热方式、加热温度、试剂用量,提高吸光度值,增加检测的稳定性。结果改进后的方法检出限为0.032 mg/L,方法的标准曲线回归方程为y=0.3077x+0.0105,线性相关系数r=0.9997。分别测定高(3.00 mg/L)、中(1.00 mg/L)、低(0.20 mg/L)3个浓度的样品,进行6次测定,相对标准偏差分别为0.85%、2.72%、4.88%,回收率为105%。结论改进后的方法可用于游泳池水中尿素的测定,该法操作简单、快速、检出限低、回收率高、稳定性强、环境污染少,能满足实验室大批量尿素样品的测定,符合实验室检测要求,为今后实现现场直接测定提供了可能性。 Objective To establish a practical,accurate and rapid method for detecting urea in swimming pool water.Methods By means of closed digestion and direct reading,the heating method,heating temperature and reagent dosage are changed to increase the absorbance value and increase the stability of detection.Results The detection limit of improved method was 0.032 mg/L.The standard curve regression equation of the method was y=0.3077x+0.0105 and the linear correlation coefficient(r)was 0.9997.The samples with high(3.00 mg/L),medium(1.00 mg/L)and low(0.20 mg/L)concentrations were measured and the relative standard deviations were respectively 0.85%,2.72%,and 4.88%.The recovery rate was 105%.Conclusion The improved method can be used for the determination of urea in swimming pool water.The method is simple,rapid,with low detection limit,high recovery rate,strong stability and less environmental pollution.It can meet the determination of large quantities of urea samples in the laboratory,comply with laboratory testing requirements to provide the possibility to achieve direct field measurements in the future.
作者 高飞 施琴芝 张璐 林峰 GAO Fei;SHI Qin-zhi;ZHANG Lu;LIN Feng(Zhejiang Xinjie Detection technology co.LTD,Ningbo,Zhejiang 315007,China)
出处 《中国卫生检验杂志》 CAS 2020年第6期659-661,665,共4页 Chinese Journal of Health Laboratory Technology
关键词 游泳池水 尿素 闭管加热 Swimming poor water Urea Closed digestion
  • 相关文献

参考文献18

二级参考文献60

共引文献46

同被引文献15

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部