期刊文献+

光电定角比相法检测圆光栅测量精度的提高 被引量:7

Improvement of measurement precision of circular raster by photoelectric phase-comparing method for angle positioning
在线阅读 下载PDF
导出
摘要 用公式推导说明了影响光电定角比相法检测圆光栅刻划误差测量精度的因素 ,并用两台测量精度不同的仪器做了实验验证。文中提出 ,在仪器稳定 ,主轴回转精度高的前提下 ,再采用分光裂相法读数 ,异或门鉴相、“内插法”、“对称联系法”等措施 。 Formula is used to explain the factors affecting the measurement precision of score errors of the circular raster by photoelectric phase-comparing method for angle positioning. It is proved that, under the conditions of high stability of the instrument and high turning precision of principal axis, the higher measurement precision can be achieved by using spectroscopic phase-splitting method for reading system, inverted OR gate for phase-discrimination, interpolation method and symmetry relation method.
出处 《光学精密工程》 EI CAS CSCD 2000年第5期482-486,共5页 Optics and Precision Engineering
关键词 圆光栅 刻划误差 测量精度 光电定角比相法 circular raster scoring errors constant angle
  • 相关文献

参考文献5

二级参考文献3

共引文献7

同被引文献38

  • 1孟中,张涛,郑秀筠,韩松伟.正交基函数多项式实时拟合在轴角编码器测速中的应用[J].光学精密工程,2006,14(2):303-307. 被引量:11
  • 2中国计量测试学会几何量专业委员会角度学组.角度学组成立十周年文选[M].,1992..
  • 3长春光机所16室检测组.检测圆光栅的光电定角比相法[J].计量技术,1983,(6).
  • 4编写组.机床设计手册-电力传动及控制系统设计[M].北京:机械工业出版社,1995.837-878.
  • 5夏士智.测量系统设计与应用[M].北京:机械工业出版社,1997.90-93.
  • 6师汉民.振动分析、辨识与建模[M].武汉:华中理工大学出版社,1998.135-136.
  • 7光电检验仪小组.码盘,光栅度盘检验仪[J].光学机械,1974,(5).
  • 8曹问群.光学刻划技术论文精选[M].机械工业出版社,1991..
  • 9肖国镇 卿斯汉.编码理论[M].北京:国防工业出版社,1990..
  • 10CHRISP M P. Aberrations of holozraohic toroidal grating systems [J]. Appl Opt , 1983,22(10) :1508-1518.