摘要 为紧急事故下应对电网大面积停电积累经验,针对国内外频发的电网大面积停电事故,湖北省电力公司先后在鄂东及鄂西北地区利用多台中小型水电机组成功地进行了黑启动试验。试验得出的主启动机组与被启动设备的先后顺序和容量估算,弱联系小网小机组与大负荷的机械、电气特性分析等可供有关人员参考。 Aiming to the large area network power cutting accidents and for accumulating experience of treating large area power cutting in emergent accident condition,the black start test was carried out by using a number of hydro-generators in east and northwest of Hubei province.The successive sequence of main start generator and started equipment,capacity evaluation was obtained by test.The mechanical and electrical characteristic of small network small generator with weak relation and large load can be reference for relative engineers.
作者 周世平
机构地区 湖北省电力公司
出处 《高电压技术》 EI CAS CSCD 北大核心 2007年第12期115-117,共3页 High Voltage Engineering
关键词 电网事故 黑启动 水轮发电机组 湖北电网 小网小机组 参数设定 network accident black start hydro-generator Hubei power electric network small network small generator parameter setting