期刊文献+

弧矢聚焦双晶单色器性能测试研究 被引量:8

Study on Checking and Measuring for Sagittal Double Crystal Monochromator
在线阅读 下载PDF
导出
摘要 针对同步辐射光束线中的弧矢聚焦双晶体单色器,研究了高准确度自准直平行光管对Bragg转角的步长分辨、转角准确度等参量检测的方法.利用单色器的双晶平行光路,可以方便实现对晶体微调角度的放大,从而检测微调机构的性能.建立了光束线模拟光路,可以实现对弧矢聚焦效果的检测.利用该方法,完成了我国第一台弧矢聚焦双晶单色器的离线检测,检测结果达到了理论设计指标,表明了测试方法的有效性. The check and measure methods of Bragg angle step and precision etc. parameters with high precision autocollimation are investigated. Adjustment angles of crystal have been magnified using parallel ray of monochromator,to checking and measuring performance of adjustment mechanism. Simulated ray of the beamline has been built to check and measure sagittal focusing facula. Performance checking and measuring of the first sagittal focusing monochromator in internal had been successfully achieved out of beamline,checking and measuring results in according with theory design index,indicating validity of those methods.
出处 《光子学报》 EI CAS CSCD 北大核心 2007年第12期2346-2349,共4页 Acta Photonica Sinica
基金 上海光源工程预置研究项目资助
关键词 弧矢聚焦双晶单色器 自准直法 Bragg角 微调机构 Sagittal focusing double crystal monochromator Autocollimation Bragg angle Adjustment mechanism
  • 相关文献

参考文献6

二级参考文献16

  • 1JOHN MACKINNON WANG SUNG.Second Annual Report Abridged of the Biodiversity Working Group (BWG) of the China Council for International Cooperation on Environment and Development (CCICED)[J].生物多样性,1994,2(B11):88-95. 被引量:1
  • 21,Lemonner M,et al.X-ray curved-crystal monochromator syste m at the storage ring dci.Nucl Instum Methods,1978,194(1):173~177
  • 32,Sparks C J,et al.X-ray monochromator geometry for focusing synchrotro n radiation above 10kev.Nocl Instum Methods,1980,172(1):237~242
  • 43,Sparks C J,et al.Sagittal focusing of synchrotron X-radiation with cu rved crystals.Nucl Instum Methods,1982,194(1):73~78
  • 54,Ice C E,et al.Focusing optics a synchrotron x-radiation microprobe.Nu cl Instum Methods,1984,222(1):121~127
  • 65,Matsushita T,et al.Sagittally focusing double-crystal monochromator w ith constant exit beam height at the photo factory.Nucl Instum Methods,1986,A246 (1):137~139
  • 76,Koyama A,et al.Improvement of the performance of sagittally focusing d ouble-crystal monochramator.Rev Sci Instrum,1992,63(1):916~919
  • 8Jean Buslnl.Design parameters for hard X-ray mirrors:the european synchrotron radiation facilfly case.Optical Engineering,1995,34(2):361~375.
  • 9Howells M R,Lunt D.Optical Engineering,1993,32(8):1981~1988.
  • 10Noda H,Namioka T,Seya M.Geometric theory of the grating.Optical Society of America,1974,64(8):1031~1036.