期刊文献+

MiniFiler试剂盒运用于法医微量物证的检验 被引量:7

Application of MiniFiler Kit in Forensic DNA Testing of Low Copy Number Template
暂未订购
导出
摘要 目的应用MiniFiler试剂盒对法医微量物证进行DNA分析。方法采用MiniFiler试剂盒对样本进行DNA分型,确定样本9个STR基因座的等位基因型。结果10pg DNA模板经MiniFiler试剂盒扩增后,能够进行DNA分型,但40pg以上的DNA方可得到稳定可靠的分型结果。结论MiniFiler试剂盒可以用于法医微量物证的STR分析。 Objective miniSTR detection kit To detect low copy number of DNA (MiniFiler) in forensic practice. forensic DNA samples were analyzed according tems, Foster City, USA). Results DNA samples the optimal DNA quantity was 40 pg or above. samples by using a newly launched commercial Methods Low concentration and/or challenged to protocols provided by the manufacturer (Applied Biosysas low as 10 pg could be amplified by MiniFiler kit, and Conclusion MiniFiler kit can be used for analysis of low copy number STR.
出处 《法医学杂志》 CAS CSCD 2007年第4期304-306,共3页 Journal of Forensic Medicine
基金 公安部应用创新计划项目(2005YYCXSHSJ001)
关键词 MiniFiler试剂盒 微量物证 法医DNA分析 miniFiler kit challenged DNA samples forensic DNA analysis
  • 相关文献

参考文献5

二级参考文献43

  • 1Gill P, Whitaker J. An investigation of the rigor of interpretation rules for STRs derived from less than 100pg of DNA[J]. Forensic Sci int,2001, 112:17-40.
  • 2Dean FB, Hosono S, Fang L, et al. Comprehensive human genome amplification L,sing multiple displacement amplification [J]. Proc Natl Acad Sci, 2002,99:5261-5266.
  • 3Hosono S, Faruqi F, Dean FB, et al. Unbiased whole-genome amplification directly form clinical samples [J].Genome Res, 2003,13: 954-964.
  • 4Ali Hellani, Serdar Coskun, Moncef Benkhalifa, et al.Multiple displacement amplification on single cell and possible PGD applications [J]. Molecular Human Reproduction, 2004,10:847-852.
  • 5CAll P, Whitaker J, Flaxman C, et al. An investigation of the rigor of interpretation rules for STRs derived from less than 100 pg of DNA [J]. Forensic Sei Int, 2000, 112:17.
  • 6Gill P. Application of low copy number DNA profiling [ J ].Croatian Medical Journal, 2001, 42:229.
  • 7Cotton EA., AUsop RF, vip JL, et al. Validation of the AMPF1STR SGM PlusTM system for use in forensic casework[J]. Forensic Sci Int, 2000, 112:151.
  • 8Whitaker JP, Cotton EA, Gill P. A comparison of the characteristics of profiles produced with the AMPF1STR SGM Plus TM multiplex system for both standard and low copy number (LCN) STR DNA analysis [J]. Forensic Sci Int, 2001,123:215.
  • 9Budowle B,Smith JA, Moretti T, et al. DNA Typing Protocols: Molecular Biology and Forensic Analysis [ M]. Massachusetts: Eaton Publishing (USA) 2000.
  • 10Buder JM. Forensic DNA typing [ M]. London: Academic press (UK), 2001. 43.

共引文献44

同被引文献65

引证文献7

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部