摘要
在一特制的可施加电场的单管熔化炉内,借助DIGIDROP DGD-DS接触角测试仪研究了元素Cr和电场对Cu/W之间润湿性的影响。结果表明:元素Cr是Cu-W熔渗体系很好的助熔渗元素,在Cu中添加元素Cr可以显著减小Cu/W之间的接触角;外加电场也可以减小Cu/W之间的接触角,在实验的电场强度内,其减小的程度不及元素Cr明显。
A special furnace was designed and applied to produce an external electrical field up to 4 kV/cm and to study the wettability between copper and tungsten. The results showed that chromium can significantly reduce the wetting angle between copper and tungsten, so benefit to Cu-W infiltration system. The electrical field can also reduce the wetting angle, but not so stronger by comparing with chromium in the experimental electrical field range.
出处
《稀有金属材料与工程》
SCIE
EI
CAS
CSCD
北大核心
2007年第6期1008-1011,共4页
Rare Metal Materials and Engineering
基金
国家自然科学基金项目(50474012)资助
关键词
润湿性
Cu/W熔渗体系
电场
CR
wettability
Cu-W infiltration system
electrical field
chromium