目的采用吹扫捕集-气相色谱/质谱联用技术(P&T-GC/MS)快速分析生活饮用水中多组分微量挥发性有机物(VOCs)。方法对解析时间、烘焙时间、烘焙流速、捕集阱填充材料和比例等P&T的条件及GC条件进行优化,并对实际水样实测分析。结果本方法操作简单、省时,一次进样可实现多组分同时测定,具有较高的灵敏度和较广的分析范围,方法的线性范围为0.5~100μg/L,最低检出浓度可达0.01~0.5μg/L,相对标准偏差为1.24%~7.79%,加标回收率在90%~110%之间。结论本方法适用于生活饮用水中多组分微量VOCs的分析。
Objective To establish a method of purge and trap in combination with gas chromatograph/mass spectrometry(P&T-GC/MS) for the rapid determination of minimum multi-mixture of volatile organic compounds(VOCs) in drinking water simultaneously. Methods The experimental conditions of P&T,such as desorption temperature, desorption time, the type of the trap and the analytical conditions of GC were optimized. 54 VOCs in drinking water were determined by P&T-GC/MS. Resdts The method enjoyed a wide linear range and good precision,the method detection limit(MDL) was 0.01 -0.5μg/L,the average recoveries of the method was 90% - 110% and the relative standard deviation (RSD) was 1.24%-7.79%. Conclusion The results showed that the method was accurate and high sensitivity and might be good for application and suitable for trace analysis of VOCs in drinking water.