期刊文献+

ACPDP功耗测试方法的探讨

Study of Measuring Method s of ACPDP's Power Consumption
在线阅读 下载PDF
导出
摘要 由于交流等离子显示板(ACPDP)放电电流的形状复杂,不能采用数学式来表达,故器件功耗的测量存在许多困难。本文介绍测量ACPDP功耗的通断法和示波器法。实验表明,前者的功耗比后者约大20%,这是由于前者包含了驱动器的功耗。 Because the shape of ACPDP's discharge current is complicated and could not be expressed by a mathematical expression, it is difficult to measure ACPDP's power consumption. The on-off method and oscilloscope checking method which are used to measure ACPDP's power consumption are presented in the paper.Experimental results show that the power consumption measured by on-off method is about 20% higher than the results obtained by oscilliscope method due to driver's power consumption.
出处 《光电子技术》 CAS 1989年第1期18-22,7,共6页 Optoelectronic Technology