期刊文献+

催化褪色光度法测定痕量铁—亚甲基蓝-铁(Ⅲ)-过氧化氢体系 被引量:3

Catalytic-Decolouration-Photometric Determination of Trace of Iron by the Reaction System of Methylene Blue-Fe-H_20_2
在线阅读 下载PDF
导出
摘要 研究了在稀H2SO4介质中,铁(Ⅲ)催化H2O2氧化亚甲基蓝的褪色反应,建立了催化动力学光度法测定痕量铁的新方法。其检出限为3.2×10-4μg·ml-1,在0.010~0.500μg/25ml范围内,铁(Ⅲ)与lgA0/A呈良好的线性关系。该方法指示反应灵敏度高,选择性好,用于食品中铁的测定,获得满意结果。 <Abstrcat>The authors studied the discoloring reaction of methylene blue by hydrogen peroxide oxidation catalyzed by trace Fe(Ⅲ) in sulphuric acid medium . In the range of 0.010~0.500 μg/25ml of Fe(Ⅲ),a good linear relation ship existe between the concentration of Fe(Ⅲ) and lg(A_0/A). The limit of detection is 3.2×10~-4μg·ml~-1. A new method with high sensitivity and selectivity for determining trace iron was established . This method was used in the determination of trace of iron in some food samples with satisfactory results.
机构地区 上饶师范学院
出处 《上饶师范学院学报》 2005年第3期52-54,共3页 Journal of Shangrao Normal University
关键词 催化动力学光度法 铁的测定 亚甲基蓝 Catalytic-kinetic spectrophotometry iron determination methylene blue