摘要 目的:从听力学角度评价畸变产物耳声发射检测对噪声性听损伤早期发现的价值。方法:利用声级计测定某食品包装材料公司生产车间噪声水平,同时利用纯音测听、声导抗、耳声发射、对生产车间接触噪声的43名工名进行听力检测并同时进行外耳检查和噪声接触史调查。结果:生产车间9个机器点的噪声水平平均93.7dB(A),超过国家规定标准85dB(A),受检的43名工名接触噪声史1~12个月,平均7个月,平时不适有15名。声导抗检测全部正常,耳声发射检测不合格的有23名,占53%,包含纯音测听不正常的有7名11耳,占16%,其中V形曲线8耳,坡形曲线3耳。16名纯音测听正常而耳声发射不合格,其中单耳不合格7名,双耳不合格9名。23名听力检测异常,其中7名纯音测听呈噪声性聋早期、中期听力损伤改变,16名纯音测听正常而耳声发射不合格。结论:利用畸变产物耳声发射技术检测接触噪声的人群,对早期发现噪声性听力损失具有一定价值。 AIM:To assess the value of distortion product otoacoustic emission (DPOAE) in screening the early noise induced hearing loss (NHIL) according to audiology. METHODS:Forty three workers in a food package manufactory received the determination of audiology and the measure of external ear and the survey of contacting noise with pure tone, acoustic immitance and DPOAE. Using acoustic metrology the noisy level in the workshop. RESULTS: The average noise level of nine machines was 93.7 dB(A), exceeding the national standard . The time of contracting noise was 1-12 months and the average time is 7 months. Fifteen workers felt unwell in normal time.Forty three workers were normal with acoustic immitance and 23 workers were abnormal with DPOAE screening, in which 11 ears of 7 workers were abnormal with pure tone measurement, including 8 V sketch and 3 descent sketch. Sixteen workers were normal with pure tone measurement but abnormal with DPOAE, in which 9 single ears of 7 workers and double ears of 9 workers were abnormal Twenty three workers were abnormal in hearing, 7 of which were early and middle stage of noise induced hearing loss change with pure tone audiometry. Sixteen workers were normal with pure tone audiometry but abnormal with DPOAE. CONCLUSION:DPOAE is a valuable method to detect people contracting noise and discover NHIL early.
出处 《中国临床康复》 CSCD 2003年第31期4266-4267,共2页 Chinese Journal of Clinical Rehabilitation
  • 相关文献

参考文献2

二级参考文献9

  • 1Arnold DJ,Lonsbury-Martin BL,MarlinGk.High-frequency hearing influences lower-frequency distortion product otoacousticemissions[J].Arch Otolaryngol Head Neck Surg,1999,125:215.
  • 2Musiek FE,Baran JA.Distortion product otoacoustic emissions:hit and false-positiverates in normal-hearing and hearing-impaired subjects[J].Am J Oto,1997,18:454.
  • 3Kim DO,Paparello J,Jung MD,Paparello Jung MD,et al.Distortion product otoacousticemission test of sensorineural hearing loss performance regarding sensitivity,specificityand receiver operating characteristics[J].Acta Otolaryngol(Stockh),1996,116:3.
  • 4Suckfull M,Schineeweiβ S,Dreher A,et al.Evaluation of TEOAE and DPOAE measurementsfor the assessment of auditory threshold in sensorineural hearing loss[J].ActaOtolaryngol(Stockh),1996,116:528.
  • 5Fausti SA,Henry JA,Schaffer HI,et al.High-frequency monitoring for early dection ofcisplatin ototoxicity[J].Arch Otolaryngol Head Neck Surg,1993,119:661.
  • 6Campbell K,Durrant J.Audiologic monitoring for ototoxicity[J].Otolaryngol ClinNorth Am,1993,26:903.
  • 7Wiley Tl,Cruickshanks KJ,Nondahl DM,et al.Aging and high-frequency hearingsensitivity[J].J Speech Lang Hear Res,1998,41:1061.
  • 8Avan P,Elbez M,Bonfils P.Click-evoked otoacoustic emissions and influence ofhigh-frequency hearing losses in humans[J].J Acoust Soc Am,1997,101:277.
  • 9刘亚光,何延军,李道德,郑素贤,牛聪敏.声预处理对强噪声引起听力损伤保护作用的研究(英文)[J].航天医学与医学工程,2000,13(5):313-317. 被引量:7

共引文献26

同被引文献24

  • 1白艳巧.飞行人员听力学保护的商榷[J].中国疗养医学,2005,14(4):252-254. 被引量:3
  • 2张霞,苗丹民,郭小朝,张雁歌,宋蕾,余文斌.歼击机噪声对人听力及工效的影响[J].中华航空航天医学杂志,2005,16(4):253-257. 被引量:11
  • 3安玉香,商丽宏,汤浩,殷萍,魏保龄.有关猫听觉脑干电反应(ABR)两耳干涉作用的研究[J].中国应用生理学杂志,1996,12(3):239-242. 被引量:2
  • 4刘富英,姚惠琳,杨秋玲,曾玉宇.预防噪声引起的听力损伤[J].劳动保护,2007(3):90-92. 被引量:7
  • 5[1]Jiang DZ. Binaural interaction and the effects of stimulus intensity and repetition rate in human auditory brain-stem. Eiectroencephalogr Clin Neurophysiol 1996;100(6): 505 - 16
  • 6[2]Laitakari K, Laitakari J. New computerized Finnish in noise test binaural hearing. Acta Otolaryngol Suppl 1997; 529:74 -6
  • 7Finitzo T,Albrigh K,O'Neal J.The newborn with hearing loss: detection in the nursery.Pediatrics 1998;102:1452- 60.
  • 8Maxon AB,White KR,Vohr BR, et al.Using transient evoked otoacoustic emissions for neonatal hearing screening.Br J Audiol 1993;27:149- 53.
  • 9Kemp DT,Ryan S,Bray P.A guide to the effective use of otoacoustic emissions.Ear Hear 1990;11: 93- 105.
  • 10Yoshinaga-Itano C,Sedey AL,Coulter DK,et al.Language of early-and later-identified children with hearling loss.Pediatrics 1998;102:1161- 71.

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部