期刊文献+

实时三维超声心动图测量左室重量的实验研究 被引量:2

Validation of real-time three-dimensional echocardiography for quantifying left ventricular mass:experimental study
暂未订购
导出
摘要 目的:探讨实时三维超声心动图(RT3DE)检测左室重量的可行性与准确性。方法:使用RT3DE系统采集10例利用双层橡胶水囊模拟的左室壁及10例离体犬心脏的左室“金字塔”型数据库,结合容积分析软件得出RT3DE左室重量值;同时用2DE的长度面积法测量左室重量;分别将RT3DE测量值、2DE测值与实际重量相比较。结果:RT3DE各平面法测量的左室重量与实际值均呈正相关(左室壁模型r=0.813~0.994,离体犬左室壁r=0.764~0.991),两者无显著性差异(P>0.05);2DE值与实际值亦呈正相关(左室壁模型r=0.628,离体犬左室壁r=0.514),两者有显著性差异(P<0.05)。RT3DE各平面法之间相比较,八平面与十六平面法之间没有显著性差异(P>0.05),而它们与两平面、四平面法之间有差异(P<0.05)。结论:实时三维超声心动图能准确测量左室重量,为评价左室功能提供了新的有力的工具。对于左室重量RT3DE测量,八平面法是准确与简便的最佳选择。 Objective:To test the accuracy of real-time three-dimensional echocardiography(RT3DE)imaging system for e-valuating left ventricular mass(LVM).Methods:Ten left ventricular(LV)wall phantoms made of two rubber-bursas,10excised canine hearts underwent RT3DE and2DE.In RT3DE'Full volume 'imaging,LVM were measured by the analysis software of RT3DE.In2DE the masses were measured by area-length method.We compared RT3DE,2DE with true mass.Results:RT3DE correlated with true masses strongly(LV wall phantoms r=0.813~0.994,excised canine hearts r=0.764~0.991)and weak-ly correlated between2DE and true masses(LV wall phantoms r=0.628,excised canine hearts r=0.514).There are no difference between RT3DE and true masses(P>0.05),but different between2DE and true masses(P<0.05).In different planes,there was no difference between8-plane and16-plane(P>0.05)but different between8-plane and2,4-plane (P<0.05).Conclusions:RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function.For RT3DE in LVM,8-plane mea-surement method is the best choice for accurance and convenience.
出处 《中国临床医学影像杂志》 CAS 2003年第5期325-327,357,共4页 Journal of China Clinic Medical Imaging
关键词 器官重量 超声心动描记术 三维 organ weight echocardiography,three-dimensional
  • 相关文献

参考文献10

二级参考文献22

  • 1[3]Ota T, Kisslo J, von Ramm OT, et al.Real-time, volumetric echocardiography: usefulness of volumetric scanning for the assessment of cardiac volume and function[J].J Cardiol, 2001, 37(Suppl 1):93-101.
  • 2[4]Schmidt MA, Freidlin RZ, Ohazama CJ, et al.Anatomic validation of a novel method for left ventricular volume and mass measurements with use of real-time 3-dimensional echocardiography[J]. J Am Soc Echocardiogr, 2001, 14(1):1-10.
  • 3[6]Grayburn PA.Current and future contrast agents[J].Echocardiography,2002,19(3):259-265.
  • 4[1]Munoz R, Marcus E, Palacio G, et al.Reconstruction of 3-Dimensional Right Ventricular Shape and Volume from 3 Orthogonal Planes[J].J Am Soc Echocardiogr,2000,13(3):177-185.
  • 5[2]Hubka M, Bolson EL, McDonald JA, et al.Three-dimensional echocardiographic measurement of left and right ventricular mass and volume: in vitro validation[J].Int J Cardiovasc Imaging,2002,18(2): 111-118.
  • 6[3]Kisslo J, Fierk B, Ota T, et al.Real-time volumetric echocardiography: the technology and the possibilities[J].Echocardiography,2000,17(8): 773-779.
  • 7[7]Schindera ST, Mehwald PS, Sahn DJ, et al.Accuracy of real-time three-dimensional echocardiography for quantifying right ventricular volume: static and pulsatile flow studies in an anatomic in vitro model[J].J Ultrasound Med,2002,21(10):1069-1075.
  • 8[1]Porter TR, Xie F, Kricsfeld A, et al.Noninvasive identification of acute myocardial ischemia reperfusion with contrast ultrasound using intravenous perfluoropropane-exposed sonicated dextrose albumin[J]. J Am Coll Cardiol, 1995, 26(1):33-40.
  • 9Ota T;Kisslo J;von Ramm OT.Real-time,volumetric echocardiography: usefulness of volumetric scanning for the assessment of cardiac volume and function,2001(Suppl 1).
  • 10Qin JJ;Jones M;Shiota T.New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging,2000(01).

共引文献126

同被引文献20

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部