期刊文献+

电感耦合等离子体-原子发射光谱法间接测定氢溴酸山莨菪碱注射液 被引量:7

Determination of Anisodamine Hydrobromide by Inductively Coupled Plasma-Atomic Emission Spectroscopy
暂未订购
导出
摘要 研究了等离子原子发射光谱法间接测定氢溴酸山莨菪碱 ( 1)。在溶液 p H5 .1~ 5 .3,四苯硼钠过量时可完全将1沉淀 ,测定滤液中剩余的四苯硼钠可以间接计算 1的含量。方法回收率为 96 %~ 10 3% ,RSD小于 2 .0 %。 The method of indirect determination of anisodamine hydrobromide by inductively coupled plasma\|atomic emission spectroscopy(ICP\|AES) was presented. The anisodamine hydrobromide was quantitatively precipitated by excess sodium tetraphenylboron in pH5.1~5.3. The boron in filtrate was determined by ICP\|AES to indirectly calculate the content of anisodamine hydrobromide. The average recovery was 96%~103% and RSD was less than 2.0%.
作者 王伟 孙为德
出处 《中国医药工业杂志》 CAS CSCD 北大核心 2003年第4期183-184,共2页 Chinese Journal of Pharmaceuticals
关键词 电感耦合等离子体-原子发射光谱法 ICP-AES 氢溴酸山莨宕碱 四苯硼钠 沉淀 测定 inductively coupled plasma-atomic emission spectroscopy anisodamine hydrobromide sodium tetraphenylboron precipitation determination