甲基硫酸新斯的明的ICP-AES测定 被引量:1

Determination of Neostigmine Methylsulfate by Inductively Coupled Plasma-Atomic Emission Spectroscopy
暂未订购
导出
摘要 研究了电感耦合等离子体原子发射光谱法间接测定甲基硫酸新斯的明 ,在溶液pH为5.0,四苯硼钠过量时可完全沉淀甲基硫酸新斯的明 ,测定滤液中的四苯硼钠可以计算得到甲基硫酸新斯的明的含量 ;方法简单快速 ,回收率在95%~101%之间 ,相对标准偏差为1.8%。 A method for the indirect determination of neostigmine methylsulfate by inductively coupled plasma - atomic emission spectroscopy(ICP - AES) was studied. In 2 mol/L NaAc-HAc buffer at pH 5.0, the neostigmine methylsulfate is completely precipitated by excessive sodium tetraphenylborate. The boron in the filtrate is detected by ICP - AES for calculating the content of neostigmine methylsulfate. The recovery of 95%~101% and RSD of less than 1.8%(n=5) were obtained for the method.
作者 王伟
出处 《分析测试学报》 CAS CSCD 北大核心 2002年第6期92-93,共2页 Journal of Instrumental Analysis
关键词 ICP-AES 药物分析 电感耦合等离子体-原子发射光谱法 甲基硫酸新斯的明 四苯硼钠 沉淀 间接测定 抗胆碱 酯酶药 Inductively coupled plasma - atomic emission spectroscopy Neostigmine methylsulfate Sodium tetraphenylborate Precipitation Indirect determination