就室内机部件对柜式空调器整机性能的影响进行了试验研究 ,研究结果表明 :室内机箱体的风阻最大 ,其次是蒸发器和进气面板 ;设计合理的进气面板能在相同气动性能的条件下降低噪声。
Carries out experiments for influence of indoor unit components on the performance of a floor standing air conditioner. A series of experiments demonstrate that the maximum flow resistance exists at the box of the indoor unit, followed by the evaporator and intake, and a properly designed intake can effectively abate the noise level. Based on the results, presents optimal design methods for performance improvement.