期刊文献+

碳中和目标下脉动真空灭菌工艺的能耗优化策略

Energy Consumption Optimization Strategies for Pulsating Vacuum Sterilization Processes under the Carbon Neutrality Goal
在线阅读 下载PDF
导出
摘要 在全球积极推动碳中和的背景下,各行业亟须探索节能减排路径。疫苗生产用具的灭菌作为关键环节,其能耗问题突出。脉动真空灭菌工艺虽灭菌效果可靠,但能耗较高。本文系统分析了该工艺的能耗现状与影响因素,并从设备升级、工艺参数优化、余热回收等方面提出具体优化策略,旨在显著降低能耗,推动疫苗生产绿色低碳转型,助力碳中和目标实现。 Against the backdrop of actively promoting carbon neutrality globally,various industries urgently need to explore energy-saving and emission reduction paths.The sterilization of vaccine production equipment is a key link,and its energy consumption problem is prominent.Although the pulsating vacuum sterilization process has reliable sterilization effect,it consumes a high amount of energy.This article systematically analyzes the energy consumption status and influencing factors of the process,and proposes specific optimization strategies from equipment upgrades,process parameter optimization,waste heat recovery,etc.,aiming to significantly reduce energy consumption,promote the green and low-carbon transformation of vaccine production,and help achieve carbon neutrality goals.
作者 武佩娴 张汶甲 WU Peixian;ZHANG Wenjia(Beijing Institute of Biological Products Co.,LTD.,Beijing 102699)
出处 《中国科技纵横》 2025年第22期171-173,共3页 China Science & Technology Overview
关键词 碳中和 脉动真空灭菌工艺 能耗优化 绿色生产 carbon neutrality pulse vacuum sterilization process energy consumption optimization green production
  • 相关文献

参考文献8

二级参考文献40

  • 1初玉云,杜丽萍,李福翠,张维传,王文涛.预真空压力灭菌器对密闭容器灭菌效果的研究[J].医疗设备信息,2004,19(4):49-50. 被引量:3
  • 2姚立宏,周晓兰,郭春梅.新型预真空压力蒸汽灭菌器实用灭菌效果观察[J].中国消毒学杂志,2005,22(1):41-42. 被引量:8
  • 3姚立宏,周晓兰,刘小辉,陈燕,周玉宝,李寅颖.PYMSI-0.6型喷射式预真空压力蒸汽灭菌器的生物监测[J].医学信息(西安上半月),2005,18(3):270-270. 被引量:1
  • 4幸桂英,王崇恒.132℃压力蒸汽灭菌化学指示卡效能测试[J].中国消毒学杂志,1997,14(1):13-16. 被引量:4
  • 5.消毒技术规范[S].[S].中华人民共和国卫生部,2002,11..
  • 6South Wood LL, Baxter GM. Instrument sterilization, skin, prepration and wound management [ J ]. Vet Clin North AM Bquine Pract,1996,12(2) :173.
  • 7Karwath P,Sartor J,Gries W, et al. Steam sterilization and automatic dispensing of fludeoxyglucose (FDG) for injection [ J]. Appl Radiat Isot ,2005,62 ( 4 ) :577 ~ 586.
  • 8Rutala WA, Jones SM, Weber DJ. Comparison of a rapid readout biological indicators for steam sterilization with our conventional biological indicators and five chemical indicators [ J ]. Infect Control Hosp Epide miol, 1996,17 (7) :423.
  • 9Stulting RD, Randleman JB, Couser JM, et al. The epidemiology of diffuse lamellar keratitis [ J ]. Cornea,2004,23 ( 7 ) :680 ~ 688.
  • 10Kakaboura A,Tzoutzas J, Pitsinigos D, et al. The effect of sterilization methods on the light transmission characteristics and structure of light-curing tips[J]. J Oral Rehabil,2004,31 (9) :918 ~923.