摘要 目的:采用2种方式将头颅锥形束CT(cone-beam CT,CBCT)数据转化为头颅侧位片,对比2组定点分析的一致性。方法:利用Dolphin软件将56例牙列完整患者的头颅CBCT数据转换为侧位片,对照组一次性投照右半侧,实验组分别对右侧6个部位投照,形成组合式侧位片。由1名资深正畸医师对23个常用标志点分别进行描迹,采用SPSS 13.0软件包中的Hotelling T2检验分析2组定点的一致性。结果:前鼻脊点、后鼻脊点、上切牙根尖点、下切缘点、下切牙根尖点、髁突点的定点差异具有统计学意义(P<0.05)。结论:组合式侧位片能更清晰地显示所需检测的解剖结构,测量的准确性更优。 PURPOSE: To study the landmark consistency on two types of cephalograms reconstructed from the data of cone-beam CT(CBCT). METHODS: CBCT data of 56 patients without teeth missing were uploaded into Dolphin software and transferred to the cephalograms. In the control group, the right half projection was taken while in the experimental group, the images achieved after 6 individual projections were managed to achieve the synthesized cephalograms. One experienced orthodontists traced the 23 frequently-used landmarks and the consistency was compared by means of Hotelling T2 test with SPSS 13.0 software package. RESULTS: The tracing of anterior nasal ridge, posterior nasal ridge,upper incisor root tip, lower incisor edge, lower incisor root tip and condyle showed significant difference( P <0.05).CONCLUSIONS: The synthesized cephalograms in the experimental group show the anatomical structure more precisely which is more beneficial to landmark identification.
作者 马晓晴 赵宁 董晛 钱文昊 MA Xiao-qing;ZHAO Ning;DONG Xian;QIAN Wen-hao(Department of Orthodontics,Shanghai Xuhui District Denial Center,Shanghai 200032;Department of Orthodontics,Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine,Slumghai 200011;Shanghai University of Medicine&Health Sciences,Shanghai 201318,China)
出处 《上海口腔医学》 CAS 北大核心 2021年第5期522-525,共4页 Shanghai Journal of Stomatology
基金 2017年徐汇区医学尖峰学科(SHXH201706) 上海市医学重点专科项目(ZK2019B12) 徐汇区医学科研项目(SHXH201915)。
关键词 锥形束CT 头颅侧位片 描迹 Cone-beam CT Cephalogram Tracing
  • 相关文献

参考文献5

二级参考文献59

  • 1李晓智,温兴涛,周建,王萍.X线片质量对手工定点可重复性的影响[J].华西口腔医学杂志,2004,22(4):342-343. 被引量:5
  • 2贾绮林,黄金芳.后前位X线头影测量分析中正中矢状定位线的评价[J].现代口腔医学杂志,1993,7(2):84-87. 被引量:22
  • 3Baumrind S,Frantz RC.The reliability of head film measurements.1.Landmark identification.Am J Orthod,1971,60:111-127.
  • 4Mah J,Hatcher DC.Craniofacial imaging in orthodontics.In:Graber TM,Vanarsdall RL,Vig KWL,editors.Orthodontics:current priniples and techniques.St Louis:Elsevier,2005,71-100.
  • 5Yoon YJ,Kim KS,Hwang MS,et al.Effect of head rotation on lateral cephalometric radiographs.Angle Orthod,2001,71:396-403.
  • 6Cho HJ.A three-dimensional cephalometric analysis.J Clin Orthd,2009,43,235-252.
  • 7Ludlow JB,Gubler M,Cevidanes L,et al.Precision of cephalometric landmark identification:cone-beam computed tomography vs conventional cephalometric views.Am J Orthod Dentofacial Orthop,2009,136:312.
  • 8Chien PC,Parks ET,Eraso F,et al.Comparison of reliability in anatomical landmark identification using two-dimensional digital cephalometrics and three-dimensional cone beam computed tomography in vivo.Dentomaxillofac Radiol,2009,38:262-273.
  • 9Waitzman AA,Posnick JC,Armstrong DC,et al.Craniofacial skeletal measurements based on computed tomography:Part Ⅰ.Accuracy and reproducibility.Cleft Palate Craniofac J,1992,29:112-117.
  • 10Waitzman AA,Posnick JC,Armstrong DC.et al.Craniofacial skeletal measurements based on computed tomography:Part Ⅱ.Normal values and growth trends.Cleft Palate Craniofac J,1992,29:118-128.

共引文献65

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部