POCT血糖仪用于血糖信息化管理中的效果评价 被引量:12

Evaluation on the Effect of POCT Glucometer in the Information Management of Blood Glucose
暂未订购
导出
摘要 目的分析在糖尿病患者血糖信息化管理中运用POCT血糖仪的效果。方法选取2017年6月—2018年6月,我院收治的糖尿病患者300例,分为对照组与观察组,各150例,对照组应用便携式血糖仪对患者血糖进行检测,人工转抄记录数据;观察组使用POCT血糖仪监测患者血糖,以IGMS平台进行数据记录,比较两组管理结果。结果管理后,观察组患者各项指标均优于对照组,P <0.05,差异具有统计学意义。结论 IGMS中应用POCT血糖仪效果良好。 Objective To analyze the effect of POCT glucometer in the information management of diabetes mellitus.Methods 300 cases of diabetes patients admitted to our hospital from June 2017 to June 2018 were selected and divided into the control group and the observation group,with 150 cases in each group.The control group was used to test the blood glucose of patients with portable glucose meter,and the data were manually transcribed.The observation group used POCT glucometer to monitor patients'blood glucose,and IGMS platform was used for data recording,and the management results of the two groups were compared.Results After management,all indexes in the observation group were significantly better than those in the control group,P<0.05,the difference was statistically significant.Conclusion POCT glucometer is effective in IGMS,and it is worth popularizing.
作者 王德才 WANG Decai(Department of Laboratory,The 5^th Division Hospital of Xinjiang Production and Construction Group,Bole Xinjiang 833400,China)
出处 《中国卫生标准管理》 2019年第4期54-57,共4页 China Health Standard Management
关键词 POCT 血糖仪 IGMS 应用效果 血糖检测 智能化管理 POCT glucometer IGMS application effect blood glucose test intelligent management
  • 相关文献

参考文献12

二级参考文献84

  • 1彭晓韧,郝虹,赵艳芳,王坚.军队高级干部急性心肌梗死与血糖管理[J].医学研究生学报,2011,24(8):847-852. 被引量:6
  • 2李子荣,史振才,郭万首,张念非,孙伟.微创小切口人工全髋关节置换术在晚期股骨头坏死治疗中的应用[J].中国修复重建外科杂志,2005,19(9):710-713. 被引量:27
  • 3樊晓萍,张环生,赵秀风,王国萍.快速血糖仪与全自动生化分析仪检测血葡萄糖结果对比研究[J].国际检验医学杂志,2006,27(3):287-287. 被引量:54
  • 4康熙雄.床旁即刻临床检测的规范化趋向[C].中华医学会第七次全国检验医学学术会议,2008:76-78.
  • 5Hasslacher C,Kulozik F,Platten I. Analytical performance of glucose monitoring systems at different blood glucose ranges and a-nalysis of outliers in a clinical setting[J]. J Diabetes Sci Technol,2014,8(3):466-472.
  • 6Junker R,Schlebusch H, Luppa PB. Point-of-care testing in hospi-tals and primary care[J3- Dtsch Arztebl Int, 2010,107 (33) ! 561-567.
  • 7Kos S, van Meerkerk A,van der Linden J, et al. Validation of anew generation POCT glucose device with emphasis on aspectsimportant for glycemic control in the hospital care[J]. Clin ChemLab Med,2012,50(9) ;1573-1580.
  • 8Louie RF, Ferguson WJ,Sumner SL, et al. Effects of dynamictemperature and humidity stresses on point-of-care glucose tes-ting for disaster care[j]. Disaster Med Public Health Prep,2012,6(3):232-240.
  • 9丁红香,徐晓杰,张美芬,倪莉.POCT血糖仪与生化分析仪血糖检测结果的比对试验及分析[J].中华检验医学杂志,2007,30(12):1374-1375. 被引量:49
  • 10中华人民共和国卫生部.卫办医政发[2010]209号医疗机构便携式血糖检测仪管理和临床操作规范(试行)[M].北京:卫生部办公厅.2010:12.

共引文献69

同被引文献106

引证文献12

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部