期刊文献+

运用失效模式与效应分析改善住院患者晨间血标本检验前流程 被引量:9

Using failure mode and effects analysis to improve the pre-analysis procedures of morning blood sample from patients
暂未订购
导出
摘要 目的针对新建三级医院的住院患者晨间血标本检验前流程,运用失效模式与效应分析(FMEA)进行改善,减少标本检验前高风险因素,降低标本拒收率、送检逾时率,提高医疗服务品质。方法运用FMEA血标本检验前流程风险评分表评估流程运行情况,探索流程失效的高风险因素,分析失效原因,采取改善措施。结果经FMEA改善后血标本拒收率由0.23%下降到0.11%,护理人员检验标本采集作业正确率由66.50%上升至92.35%,患者晨间血标本送检逾时率明显改善。结论 FMEA可明显改善新建三级医院住院患者晨间血标本检验前流程。 Objective To improve the pre-analysis procedures of morning blood sample from patients in newly-established tertiary hospitals.Failure mode and effects analysis(FMEA)were applied to decrease high-risk factors before sample analysis,minimize the rejection rate and overdue rate of sample,and enhance medical service quality.Methods The FMEA mark sheet on risks in pre-analysis procedures of blood sample was used to assess the operations,identify risk factors of process failure,analyze the reasons for process failure,and adopt measures of improvement.Results After the improvement of failure mode and effects analysis,the rejection rate of sample decreased from 0.23%to 0.11%,the accuracy of sample collection by nurses increased from 66.50%to 92.35%,and the overdue rate of morning blood sample was significantly improved.Conclusion FMEA can obviously improve the pre-analysis procedures of morning blood sample from patients in newly-established tertiary hospitals.
作者 石东辉 许育 刘军 李梦澹 SHI Donghui;XU Yu;LIU Jun;LI Mengdan(Huashan North Hospital,Fudan University,Shanghai 201907,China)
出处 《中国卫生资源》 北大核心 2018年第2期176-179,共4页 Chinese Health Resources
关键词 失效模式 效应分析 血液标本 检验前流程 failure mode effects analysis blood sample pre-analysis procedure
  • 相关文献

参考文献6

二级参考文献77

  • 1苏兰若,王爱平,谢淑娟.对我院护理工作量的3次调查及分析[J].护理管理杂志,2004,4(9):16-17. 被引量:22
  • 2王泓,叶文琴,王伟智,仲继红,曹涌.心胸外科监护室护理工作量调查及人力资源的合理使用[J].中华护理杂志,2004,39(8):604-606. 被引量:27
  • 3叶文琴,杜萍,徐筱萍.上海市护理人力资源配置现状研究[J].中华护理杂志,2006,41(10):874-877. 被引量:35
  • 4黄忠琴,陈海生.187例不合格检验标本的原因分析及护理管理对策[J].护理管理杂志,2007,7(5):39-40. 被引量:17
  • 5申子瑜,杨振华,王治国,等.医院管理学-临床实验室管理分册.北京:人民卫生出版社,2003,5:58-73.
  • 6Paolo C,Mario,Errors in a stat laboratory: types and frequencies 10 years later.Clinical Chemistry,2007,53(7): 1338-1342.
  • 7Viroj W.Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6-month monitoring.BMC Clinical Pathology,2001(1):5.
  • 8Alisna MJ,Alrarezv,BarbaN,et al,Preanalytical quality control program-an overview of results (2001-2005 summary).Clin Chem Lab Med,2008, 46(6):849-854.
  • 9Bruce AJ,Roger RC,Peter JH.Chemistry specimen acceptability:a college of american pathologists Q-Probes study of 453 laboratories.Arch Pathol Lab Med,1997(121): 9-26.
  • 10Bruce AJ,Frederick M,Peter JH. Complete blood count specimen acceptability: a college of american pathologists Q-Probes study of 703 laboratories.Arch Pathol Lab Med,1995(119): 203-208.