储油罐顶对壳的弱连接结构 被引量:9

Weakly Connecting Struture between Roof and shell of Oil Storage Tank
在线阅读 下载PDF
导出
摘要 本文根据立式固定项油罐顶对壳连接结构特点,以API650规范F—6附录标准计算了顶对壳弱连接的失稳压力,讨论了罐底不被抬起的临界条件,对罐顶和罐壁采用弱连接与非弱连接设置紧急排气阀的必要性提出了自己的观点。 Based on the characteristics of roof-to-shell connecting structure of Tertical fixing roof oil tank,this paper calculates the instable pressure of weak connection between roof and shell in accordance with API 650, Appendix F-6 . It also discusses the critical condition in which tank bottem would not be lifted, and explains its own position on the question of whether urgent gas relieve valve shall be installed if roof and she'll of oil tank utilize weak connection and unweak connection.
作者 孙正国
出处 《油气储运》 CAS 北大核心 1991年第1期41-46,共6页 Oil & Gas Storage and Transportation
  • 相关文献

同被引文献53

  • 1武铜柱.大型立式油罐发展综述[J].石油化工设备技术,2004,25(3):56-59. 被引量:58
  • 2惠虎,宋虎堂,吴云龙,李培宁.大型原油储罐的有限元强度分析[J].油气储运,2004,23(12):21-25. 被引量:24
  • 3应宏伟,杨晓刚,卞守中,潘秋元,谢康和.大型油罐地基现场试验分析[J].岩土工程学报,2005,27(2):157-161. 被引量:22
  • 4徐乃欣,邱枫,张承典.阴极保护系统中电位分布的数值计算[J].腐蚀与防护,1995,16(6):249-252. 被引量:6
  • 5Slone. Dynamics Fluid-structure Interaction Using Finite Volume Unstructured Mesh Procedures[J]. Computers and Structures, 2002,80(5) : 371-380.
  • 6Malhotra. Uplifting Response of Unanchored Liquid Storage Tanks[J]. Journal of Structural Engineering, 1994,20(12) : 525-546.
  • 7Martin Prager. Investigation of Frangibility of Geodesic Dome Roofs Used in Aboveground Storage Tanks[J]. Welding Research Council Progress Reports, 2005,60 (3) :3-37.
  • 8Morgenegg E. New Design Rules for Frangible Roof Tanks [J]. Hydrocarbon Processing, 1978,57 (8) : 11-14.
  • 9Zhi Lu. Evaluation of Design Criteria for Storage Tanks with Frangible Roof Joints [M]. Washington: American Petroleum Institute, 1996 :1-10.
  • 10API650-2008,钢制焊接油罐[S].

引证文献9

二级引证文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部