摘要
介绍了虹源发电有限责任公司 2× 135MW机组采用的流态化仓泵气力输灰系统 ,提出了调试过程中发现问题的解决方案 。
The Guilin Hongyuan power plant installed 2×135MW units.Their fly ash is removing with a fluidized pump air conveyor system.In course of debugging,it was found that a few of problems existed in the system.Among them,the ash pipe blockage was a key problem.Some of them have been solved in debugging,but some have to be solved in the future.
出处
《电力环境保护》
2002年第1期45-49,共5页
Electric Power Environmental Protection
关键词
流态化仓泵
输灰
调试
堵管
fluidized pump
fly ash convey
debugging
blockaged pipe