氟、磷酸根和六氟磷酸根离子在流速为 0 .2 5ml·min- 1,淋洗液为 0 .0 0 1mol·L- 1Na2 CO3和 0 .0 0 5mol·L- 1NaOH溶液 ,在离子色谱仪上能较好地分离。氟、磷酸根和六氟磷酸根离子的检出限分别为 7.2 9,70 .5和 2 95ng·ml- 1,该方法具有良好的线性 ,测定结果有较好的重现性。
It is reported that fluoride, phosphate and hexafluorophosphate ions were successfully separated by ion chromatography using a mixed eluent composed of 0.001mol·L -1 Na 2CO 3 and 0.005mol·L -1 NaOH at a flow rate of 0.25ml·min -1 . The detection limits ( S/N =3) found are 7.29, 70.5 and 295ng·ml -1 for fluoride, phosphate and hexafluorophosphate ions respectively. Good linearity and repeatability are proved by experimental results. The above mentioned method has been satisfactorily applied to the analysis of lithium hexafluorophate.
出处
《理化检验(化学分册)》
CAS
CSCD
北大核心
2001年第7期313-315,共3页
Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基金
浙江省自然科学基金
浙江省分析测试基金资助项目