摘要 凝结水精处理系统混床运行的终点通常只靠氢电导率指标予以控制,其缺点是终点判断不够准确。离子色谱仪可快速、准确地检测出高纯水中痕量杂质离子含量,因而可辅助混床运行终点的判断。此外,当凝结水精处理系统混床运行和再生出现问题时还可利用离子色谱测试技术分析问题所在。结合电厂实际,详细介绍离子色谱测试技术在凝结水精处理系统中运用的情况。 The end point of mixed bed operation in condensate polishing system is commonly cotrolled only by hydrogen conductivity index,its defect is unaccurate judgement of the end point.The ion chromatography can rapidly and accurately detect the ion content of trace impurities in highly pure water,hence,it is helpful to judge the end point of mixed bed operation.Furthermore,in the case of problem occurring in mixed bed operation and regeneration of the condensate polishing system,the ion chromatographic technology can also be used to analyse where the problem lies.Combined with practice in power plants,the application situation of ion chromatographic technology in condensate polishing systems has been presented in detail.
出处 《热力发电》 CAS 北大核心 2011年第10期81-84,共4页 Thermal Power Generation
关键词 离子色谱 凝结水 精处理 混床 钠离子 氯离子 ion chromatography condensate polishing mixed bed sodium ion chlorine ion
  • 相关文献

参考文献4

二级参考文献10

  • 1BEVERLY NEWTOW.Innovative products and applications for the analysis of power waters using ion chromatography.1998 International Water Conference
  • 2第七届全国离子色谱学术报告会论文集[C].杭州.1999.10.
  • 3Dionex公司技术交流资料.离子色谱在电力工业系统的应用[R].1999.
  • 4王杏卿主编.热力设备的腐蚀与保护[M].北京:水利电力出版社.1998.
  • 5Electric Power Research Institute;Report TR-102134,PWP Secondary Water Chemistry Guidelines,Palo Alto,CA,May, 1993.
  • 6Pohl C.Saini SJogodzinski J.A New Isocratic,Hydroxide Selective Anion Exchange Phase for Ion Chromatography,presented at the Pittsburgh Conference,1998.
  • 7Liu Y.Avdalovic N.;Small H,:Matt R.:Dhillon H.online large Capacity High-Purlty Acid and Base Generation Devices and Their Application in Ion Chromatography.pressented at the Pittsburgh Conference, 1998.
  • 8Batreto V.;Kirkland A.;Jackson P.;Riviello J.Optimization of the Ion Exchange Capacity of Self-Regenerating Suppressors in Ion Chromatography,presented at the Pittsburgh Conference,1998.
  • 9Heheding S.S.Maintaining Good Control of Water Chemistry with Ion Chromatography In Power Applications,Ultrapure water,Sept.1996,62-66.
  • 10Proceeding of the American Power Conference,1983-1987.

共引文献25

同被引文献62

引证文献6

二级引证文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部