摘要
简要分析了原苏联 1 95 7年热力计算标准、 1 973年热力计算标准和美国CE锅炉性能设计标准的区别 ,依据三种标准编制了计算程序 ,对 HG- 4 1 0 / 1 0 0 - 9型、HG- 6 70 / 1 40 - 9型和 DG- 1 0 2 5 / 1 77- 2型锅炉分别进行计算 ,通过对计算结果的比较 ,初步总结了三种标准对锅炉不同容量的适用性 ,该项研究对锅炉工程技术人员有一定的参考价值。
In this paper,author analyses the deference among Soviet Thermal Power Computation Standard(1957),Soviet Thermal Power Computation Standard(1973)and American CE Boiler Performance Design Standard,then compiles three programs according to the three standards.And the author computes three boilers using these programs.These boilers are HG\|410/100\|9,HG\|670/140\|9 and DG\|1025/177\|2.By contrasting the results of computation of three boilers,the author draws a primary conclusion about the application range of these standards.The conclusion can help boiler engineers in actual projects.
出处
《现代电力》
2001年第1期8-14,共7页
Modern Electric Power
关键词
电站
锅炉
热力计算标准
流放热系数
boiler
thermodynamic calculation
calculation criteria
comparison