期刊文献+

高温对流过热器布置方式对锅炉运行经济性影响的分析

Analysis of Influence of Intense Convection Recuperator Collocation Mode on the Economy of Boiler Operating
原文传递
导出
摘要 下花园发电厂 3号炉自投产以来 ,高温对流过热器曾数次出现超温、爆管现象。针对这一问题 ,在深入调研的基础上 ,进行了全方位的分析和计算 ,提出了改造方案 :高温对流过热器整体翻转 180°、并增加受热面。该厂进行了改造后的试运行、热力试验和验收工作。全部焊口都进行了射线检查 ,焊接质量的一次合格率大于 98% ,改造后主汽温度达到额定值 ,锅炉效率提高了 0 4 4%。本次改造的成功 。 Since No 3 boiler of Xiahuayuan Power Plant going into operation, there had been the phenomena of overheating and tube rupture in intense heat convection recuperator The overall analysis and computation were done for this problem on the basis of deep survey and research, and the alteration solution was put forward: intense heat convection recuperator was reversed 180° and the heating surface was increased Xiahuayuan Power Plant made trail operation, thermal test, check and acceptance for the recuperator after the alteration It is found that the qualified rate of weld quality exceeded 97 percent after all welded seams were inspected with rays The temperature of live steam reached rated value, and boiler efficiency has increased 0 44 percent after alteration This success in the alteration has engineering practical value and guidance meaning for the same type of the boilers
出处 《现代电力》 2003年第5期1-5,共5页 Modern Electric Power
关键词 锅炉 运行经济性 高温对流过热器 布置方式 下花园发电厂 boiler intense heat convection recuperator overheating alteration welding
  • 相关文献

参考文献8

二级参考文献15

  • 1王雅勤.锅炉燃烧室传热计算方法的研究[J].河北电力技术,1986,(2):6-16.
  • 2北京锅炉厂(译).锅炉机组热力计算标准方法[M].北京:机械出版社,1973..
  • 3普华煤燃烧技术中开发心.联邦德国锅炉性能设计计算方法[M].-,1992..
  • 4冯俊凯.锅炉原理与计算[M].北京:科学出版社,1987..
  • 5刘林华.锅炉传热计算方法的发展状况[J].动力工程,2001,1(20).
  • 6团体著者,盐城电厂8号炉炉内温度场测试校核试验报告,1993年
  • 7赵又仁,炉内温度场计算与测试对比分析,1993年
  • 8孙昭星,Advances in Power Engineering,1992年
  • 9孙昭星,A Study on the Method of Calculation of Three Dimensional Heat Transfer in Boiler Combustors,1987年
  • 10孙昭星,动力工程,1984年,5期