A double-layer uncooled thermistor infrared detector based on standard CMOS technology
原文传递
导出
摘要 采用0.5μm标准CMOS工艺和微机械加工工艺,设计并制作了低成本双层非制冷热敏电阻型红外探测器。探测器采用隐藏桥腿式微桥结构,使用表面牺牲层技术实现,其中包括Al、W和Si3种牺牲层材料。CMOS工艺加工完成后,双层微桥结构的微机械加工过程只需进行湿法腐蚀即可,成本较低。对双层红外探测器的热性能和光电特性进行测试,其热导为1.96×10-5 W/K,热容为2.23×10-8 J/K,热时间常数为1.14ms。当红外辐射调制频率为10Hz时,双层红外探测器的电压响应率为2.54×104 V/W,探测率为1.6×108 cm·Hz1/2/W。 This paper develops a low-cost double-layer uneooled thermistor infrared detector based on standard 0.5 μm CMOS technology and micromachining processes. The double-layer infrared detector employs a hidden-bridge-leg micro-bridge structure with a 55 μm× 55 μm bridge deck,two 7.5 btm width hidden bridge legs and an aluminum thermistor. The micro-bridge structure is implemented by the sur- face sacrificial layer technology without any additional lithography or thin film deposition procedure. The sacrificial layers include three materials, aluminum, tungsten and polysilicon. The double-layer infrared detector has a size of 65μm × 65μm and a fill factor of 71.6 %. The temperature coefficient of resistance (TCR) of the aluminum thermistor is about 0. 419%K in a muffle furnace whose temperature varies from 10 ℃ to 100 ℃ The thermal conductance of the double - layer infrared detector is calculated as 1.96 × 10-5 W/K by measuring responses to different heating currents from 0.3 mA to 4. 8 mA. The fabricated infrared detector is irradiated by an infrared laser which is modulated bya tnechanical chopper in a frequency range of 10-1000 Hz. Measurements show that the thermal time constant is 1.14 ms and the thermal mass is 2.23 × 10-8 J/K. The responsivity of the infrared detector is about 2.54 × 104 V/W at 10 Hz and the calculated detectivity is 1.6× 108 cmHz1/2/W.
出处 《光电子.激光》 EI CAS CSCD 北大核心 2014年第5期845-850,共6页 Journal of Optoelectronics·Laser
基金 国家自然科学基金(61131004 61274076)资助项目
关键词 CMOS红外探测器 非制冷红外探测器 低成本红外探测器 多牺牲层 双层红外探测器 CMOS infrared detector uncooled infrared detector low-cost infrared detector multi- sacri-ficial layers double-layer infrared detector
  • 相关文献

参考文献15

二级参考文献91

  • 1沈楠,李毅,易新建.纳米VO_2薄膜的制备及其可见光透过率的改善[J].红外与毫米波学报,2006,25(3):199-202. 被引量:24
  • 2熊大元,曾勇,李宁,陆卫.甚长波量子阱红外探测器光栅耦合的研究[J].物理学报,2006,55(7):3642-3648. 被引量:8
  • 3李金华,袁宁一,谢太斌,但迪迪.超高温度系数V_(0.97)W_(0.03)O_2多晶薄膜的制备研究[J].物理学报,2007,56(3):1790-1795. 被引量:12
  • 4刘兴明,韩琳,刘理天.非晶硅室温微测辐射热计的研制[J].红外与激光工程,2007,36(3):329-332. 被引量:3
  • 5Morin F J. Oxides which show a metal-to-insulator transition at the neel temperature[J]. Phys Rev Lett,1959,3(1):34-36.
  • 6Chain, E E. Optical properties of vanadium dioxide and vanadium pentoxide thin films[J]. Appl Opt, 1991, 30 (19) : 2782- 2787.
  • 7Chen S H, Ma H, Yi X J, et al. Optical switch based on vanadium dioxide thin films [J]. Infrared Physics and Technology, 2004,45(4) : 239-242.
  • 8Kato K, Song P. K, Odaka H, et al. Study on thermochromio VO2 films grown on ZnO-coated glass substrates for smart windows[J]. Jpn J Appl Phys,2003,42(10) :6523-6531.
  • 9Lysenko S, Rua A, Vikhnin V, et al. Light-induced ultrafast phase transitions in VO2 thin film[J]. Applied Surface Science, 2006,252(15):5512-5515.
  • 10Dmitry R, Kevin T Z, Venkatesh N, et al. Structure-functional property relationships in rf-sputtered vanadium dioxide thin films[J]. Journal of Applied Physics, 200 ?, 102 (11) : 113715.

共引文献19

同被引文献54

  • 1余隽,唐祯安,陈正豪,魏广芬,王立鼎,闫桂贞.基于硅微加工工艺的微热板传热分析[J].Journal of Semiconductors,2005,26(1):192-196. 被引量:10
  • 2张凤田,唐祯安,高仁璟,金仁成,郭文泰,王海霞.微热板式气压传感器结构设计与热分析[J].光学精密工程,2004,12(6):598-602. 被引量:12
  • 3柏成玉,原遵东,王铁军.红外耳温计的校准[J].计量技术,2007(4):46-49. 被引量:9
  • 4American Society for Testing and Materials. E1965-98, Standard specification for infrared thermometers for inter- mittent determination of patient temperature [S]. West Conshohocken: ASTM, 2003.
  • 5European Committee for Standardization. EN 12470-5: 2003(E) ,Clinical thermometers. Performance of infra-red ear thermometers (with maximum device)[S~. Brussels: CEN,2003.
  • 6Japanese Standards Association. JIS T-4207, Infrared ear thermometersES~. Tokyo: JSA, 2005.
  • 7Tsai S. Comparison measurements of infrared ear ther- mometers against three types of blackbody sources[J]. Int J Thermophys, 2010,31 : 1821-1831.
  • 8ZHU Ying-song. - 50 to 4- i50 ~C heat pipe blackbody source for radiation thermometer calibrationr-A~. Proc. of Temperature; its measurement and control in science and industry[C]. 1982,559-565.
  • 9Hollandt J, Friedrich R, Gutschwager B, et al. High-accu- racy radiation thermometry at the national metrology in- stitute of germany, the PTB[J]. High Temperatures-High Pressures, 2003/2004,35/36 : 379-415.
  • 10Drury M D, Perry K P, Land T. Pyrometers for surface temperature measurement[J]. J. Iron. Steel. Inst., 1951, 169:245-250.

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部