期刊文献+

胎儿心腔内高回声结构后方彩色多普勒闪烁伪像的超声观察及临床意义 被引量:2

原文传递
导出
摘要 以往国内外许多学者对产科常规超声检查中常发现的胎儿心腔内高回声结构(intracardiac hyperechogenic focus,ICEF)做过多方面的系统研究,发现ICEF与胎儿染色体异常综合征(13-三体及21-三体综合征)相关联,有研究认为超声检出单纯心腔内ICEF提示胎儿伴发心脏结构或功能异常的风险加大。
出处 《中华医学超声杂志(电子版)》 2014年第3期41-43,共3页 Chinese Journal of Medical Ultrasound(Electronic Edition)
基金 杭州市医药卫生科技计划项目(2011A047)
  • 相关文献

参考文献14

  • 1Levine D, Mehta TS, Min KK, et al. Technical factors influencing sonographic visualization of fetal echogenic intracardiac foci[J]. J Clin Ultrasound, 2000, 28(9): 479-484.
  • 2Huang SY, Shaw SW, Cheuh HY, et al. Intracardiac echogenic focus and trisomy 21 in a population previously evaluated by first-trimester combined screening[J]. Acta Obstet Gynecol Scand, 2010, 89(8): 1017-1023.
  • 3Bradley KE, Santulli TS, Gregory KD, et al. An isolated intracardiac echogenic focus as a marker for aneuploidy[J]. Am J Obstet Gynecol, 2005,192(6): 2021-2026.
  • 4Brunese L, Romeo A, Iorio S, et aI. A new marker for diagnosis of thyroid papillary cancer: B-flow twinkling sign[J]. J Ultrasound Med, 2008,27(8): 1187-1194.
  • 5Tsao TF, Kang RJ, Tyan YS, et al. Color Doppler twinkling artifact related to chronic pancreatitis with parenchymal calcification[J]. Acta Radiol, 2006, 47(6): 547-548.
  • 6Lai WW, Geva T, Shirali GS, et al. Guidelines and standards for performance of a pediatric echocardiogram: a report from the Task Force of the Pediatric Council of the American Society of Echocardiography[J]. JAm Soc Echocardiogr, 2006, 19(12): 1413-1430.
  • 7Rahmouni A, Bargoin R, Herment A, et al. Color Doppler twinkling artifact in hyperechoic regions[J]. Radiology, 1996, 199(1): 269-271.
  • 8Wang M, Li J, Xiao J, et al. Systematic analysis of factors related to display of the twinkling artifact by a phantom: an optimized investigation[J]. J Ultrasound Med, 2011, 30(11): 1449-1457.
  • 9Zhao BW, Yang Y, Pan M, et al. Color Doppler twinkling artifact in fetuses with echogenic intracardiac foci: echocardiographic observation and clinical significance[J]. Ultrasound Obstet Gynecol, 2010,35(5): 548-551.
  • 10Kamaya A, Tuthill T, Rubin JM. Twinkling artifact on color Doppler sonography: dependence on machine parameters and underlying cause[J]. AJRAm J Roentgenol, 2003,180(1): 215-222.

二级参考文献56

  • 1佘志红,王慧芳,林琪,熊奕,卢峻,彭启慧,魏章洪,冯晓凤,吴瑛,林琳华,任景慧.中孕期胎儿超声筛查切面的规范化探讨[J].中华超声影像学杂志,2005,14(1):39-41. 被引量:66
  • 2李胜利,欧阳淑媛,陈琮瑛,刘菊玲,毕静茹,姚远,官勇,廖玉媚,罗福薇,文华轩.四腔心平面头侧偏斜法快速筛查胎儿先天性心脏畸形[J].中华超声影像学杂志,2005,14(8):594-596. 被引量:127
  • 3Harada K,Tsuda A, Orino T, et al. Tissue Doppler imaging in the normal fetus. Intern J Cardiol, 1999,71 : 227-234.
  • 4Chan LY,Fok WY,Wong YF, et al. Reference charts of gestation- specific tissue Doppler imaging indices of systolic and diastolic functions in the normal fetal heart. Am Heart J, 2005,150: 750-755.
  • 5Levine D, Mehta TS, Min KK, et al. Technical factors infIuencing sonographic visualization of fetal echogenic intracardiac foci. J Clin Utrasound, 2000,28:479-484.
  • 6Sepulveda W, Cullen S, Nicolaidis P, et al. Echogenic loci in the fetal heart: a marker of chromosomal abnormality. Br J Obstet Gynecol, 1995,102 : 490-492.
  • 7How HY,Villafane J,Parihus RR, et al. Small hyperechogenic foci of the cardiac ventricle: a benign sonographic finding? Ultrasound Obstet Gynecol, 4994,4:205-207.
  • 8Nagueh SF,Sun H, Koplen HA, et al, Hemodynamic determinants of the mitral annulus diastolic velocities by tissue Doppler. J Am Coll Cardiol,2001,37 : 278-285.
  • 9Degani S, Leihovitz Z, Shapiro I, et al. Cardiac function in fetuses with intracardiae echogenie foci. Ultrasound Obstet Gynecol, 2001, 18 : 131-134.
  • 10Roberts DJ, Genest D. Cardiac histopathology characteristics of trisomies 13 and 21. Hum Pathol, 1992,23 : 1130-1140.

共引文献150

同被引文献17

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部