期刊文献+

现场光化学荧光法测定酪氨酸 被引量:8

In-situ Photochemical Fluorimetry of Tyrosine and Its Determination
在线阅读 下载PDF
导出
摘要 在氨性缓冲溶液中,酪氨酸经275nm紫外光照射后,产生荧光二聚体。据此,建立了现场光化学荧光法测定酪氨酸的新方法。线性范围为 2.0 × 10-7~ 2.0 × 10-5 mol/L。检测限及精密度分别为 3.2 × 10-9mol/L-1和 1.7%。方法简便、快捷,对其它氨基酸有较好的选择性,可用于啤酒及氨基酸注射液的测定。文章对光化学反应机理作了初步探讨。 Tyrosine can produce fluorescent dimers under irradiation with 275nm UV-light in NH3-NH4CI buffer. Besed on this fact, a new photochemical fluorimetry in-situ was developed for determination of tyrosine. The linear relationship is over the range of 2. 0 x 10-7 - 2. 0 x 10-5 mol/L tyrosine. The detection limit is 3 .2 x 10-9 mol/L and relative standard deviation is 1 .7%. This method is simple and rapid, and has better selectivity for other amino-acids. It has been applied to the determination of tyrosine in beer and amino-acid injections. Mechanism of the photochemical reaction was discussed.