期刊文献+

自攻型微种植支抗钉在矫治下颌磨牙舌倾中的应用 被引量:4

Clinical application of miniscrew implant anchorage for treatment of mandibular molar linguoclination
暂未订购
导出
摘要 目的评价自攻型微种植支抗钉治疗下颌磨牙舌倾的有效性。方法选择8例下颌磨牙舌倾的正畸患者,应用自攻型微种植支抗钉牵引11颗舌倾的下颌磨牙。分别在微种植支抗钉植入前和取出后拍摄曲面断层片和头颅侧位片,并进行头影测量及模型测量分析。结果 8例患者所植入的自攻型微种植支抗钉在矫治过程中均保持稳定;舌倾的磨牙均得到有效的直立,矫治后下颌磨牙间宽度增加4.5 mm,与矫治前相比下颌磨牙宽度变化差异有统计学意义(P<0.01);下颌磨牙高度降低1.2 mm,有统计学意义(P<0.05);而下颌平面角(MPSN)及面下高与全面高之比(ANS-Me/N-Me)变化差异无统计学意义(P>0.05)。结论自攻型微种植支抗钉可有效地直立舌倾的下颌磨牙,避免磨牙伸长,磨牙咬合关系良好。 Objective To evaluate the efficiency of miniscrew implant anchorage tor treatment of mandibular molar linguoclination. Methods Eight patients with mandibular molar linguoclination were selected for this study. The miniscrew implant were inserted into the buccal interalveolar septum between the first molar and the second molar as a direct am'borage. Pre-treatment and post-treament cephalometric radiographs were taken and analysed. Results All the miniscrew implants kept stable during the treatmenh The posterior teeth tilting lingually were upreared buceally, the width of mandibular morals increased and the resuhs showed statistically significant difference ( P 〈 0.01 ). There was no statistically significant differenee in MP-SN and ANS-Me/N-Me variation ( P 〉 0.05). Conclusion The miniscrew implants couht be used as an efficient method to correct mandihular molar linguoelination by uprearing huccally the tilting low posterior teeth.
作者 刘启明
出处 《广东牙病防治》 2013年第9期489-491,共3页 Journal of Dental Prevention and Treatment
关键词 微种植支抗钉 磨牙舌倾 头影测量分析 Micro-impant anehorage Molar linguoclination Cephalometric analysis
  • 相关文献

参考文献10

二级参考文献102

共引文献59

同被引文献31

  • 1张忠.转矩方弓和交互牵引矫治磨牙深覆盖的临床研究[J].口腔医学研究,2006,22(6):681-683. 被引量:3
  • 2唐顼晶,刘月华,兰庭超.第二恒磨牙正锁(牙合)畸形相关因素的研究[J].上海生物医学工程,2007,28(2):100-103. 被引量:19
  • 3McAboy CP,Grumet JT,Siegel EB.Surgical uprighting and re-pos- itioning of severely impacted mandibular second molars[J]J Am Dent Assoc,2003,134(11):1459-1462.
  • 4Bae SM,Park HS,Kyung HM,et al.Clinical application of micro implant anchorage[J].J Clin Orthod,2002,36(5):298-302.
  • 5Florvaag B,Kneuertz P,Lazalr F,el al.Biomechanical properties of orthodontic miniscrews.An in-citro study[J].J Orofac Orthop,2010,71(1):53-67.
  • 6Deguchi T,Nasu M,Murakami K,et al.Quantitative evaluation of Cortical bone thickness with computed tomographic scanning for or-thodontic implants.Am J Orthod Dentofacial Orthop,2006,129(6):721-727.
  • 7Poggio PM,Incorvati C,Velo S,et al.Safe zonesra guide for miniscrew positioning in the maxillary and mandibular arch.Angle Orthod,2006,76(2):191-197.
  • 8Erverdi N,Usumez S,Solak A,et al.Noncompliance open-bite treatment with zygomatic anchorage.Angle Orthod,2007,77(6):986-990.
  • 9Papageorgiou SN,Zogakis IP, Papadopoulos MA.Failure rates and associated risk factors of orthodontic miniscrew implants:a meta-analysis[J].Am J Orthod Dentofacial Orthop,2012,142(5):577-595.
  • 10Lim HJ,Choi YJ,Evans CA,et al.Predictors of initial stability of orthodontic miniscrew implants[J].Eur J Orthod, 2011,33(5):528-532.

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部