摘要
烟气排放连续监测系统(CEMS)的作用是指导烟气脱硫系统的运行和对脱硫后烟气的排放进行监测。介绍了由于CEMS的测点位置选取不当而引发问题的两个案例,分析和探讨了产生此问题的原因,并提出了改进措施,对电厂CEMS的维护和管理有一定的指导意义。
The role of Continuous Emission Monitoring System(CEMS) is guiding the operation of the flue gas desulfurization system and monitoring the emissions of flue gas desulfurization.Two cases of problems caused by the improper selection CEMS measuring point are describde.The reasons of the problem are analyzed and discussed,and improvement measures are proposed,which provides some guiding significance for the maintenance and management of the CEMS.
出处
《电力科技与环保》
2013年第4期54-56,共3页
Electric Power Technology and Environmental Protection
关键词
CEMS
测点位置
脱硫系统
CEMS
measuring point
desulfurization system