介绍了烟气排放连续监测系统的使用现状;依据雷电学原理及相关防雷技术规范,分析了烟气排放连续监测系统遭雷击的原因及其防雷方面存在的问题;综合运用隔离、屏蔽、合理布线、等电位联结以及接地等现代防雷技术手段,从防雷专业角度提出了相关问题的解决方法。
The using actuality of continuous emissions monitoring systems(CEMS)was expounded. An analysis to the reasons that CEMS suffer lightning strike and the problems on lightning protection of it was conducted by applying the lightning principle and relevant technical specifications of lightning protection system. And professional solutions on lightning protection to these problems were proposed by using modern lightning protection technologies such as isolation, shielding, rational wiring, equipotential bonding and grounding.
出处
《中国科技信息》
2013年第7期105-106,共2页
China Science and Technology Information
关键词
烟气排放连续监测系统
防雷
隔离
屏蔽
合理布线
等电位联结
接地
continuous emissions monitoring systems (CEMS)
lightning protection
isolation
shielding
rational wiring
equipotential bonding
grounding