期刊文献+

ARRIF的研制及生物力学的测试 被引量:7

BIOMECHANICAL TEST OF ANTI - ROTATION REDUCTION INTERNAL FIXA-TORS
暂未订购
导出
摘要 目的:研制一种适用于胸腰段脊柱骨折的新型简便的抗旋转复位内固定器。方法:用6具新鲜健康成年人胸_(11)~腰_3椎体标本,分别制成屈曲压缩骨折模型及屈曲牵张型损伤模型,将6副ARRIF分别固定于胸_(12)~腰_2椎弓根内,测试标本承受轴向压应力、左右侧弯应力、屈伸应力和左右旋转应力的情况,为临床应用提供可靠的实验依据。结果:ARRIF能承受5000N的压应力,1000N的屈伸应力,500N的侧弯应力,及较好的抗旋转能力。结论:ARRIF具有确实的三维固定作用,对于脊柱骨折具有稳定的固定作用。 Objective: To test biomechanical effects of anti - rotation reduction internal fixators (ARRIF) on spinal fracture. Methods: Six healthy adult's T11 - L3 vertebral specimens were made into the models of flexion compression and flexion split fracture and these models were fixed by ARRIF at pedicles. Then the longitudinal pressure, flexion -extension pressure, lateral bending pressure and axis rotation pressure were measured. Results: ARRIF could bear 5000N pressue stress, 1000N flexion -extension stress, 500N lateral bending stress. It also had better anti -rotation effect. Conclusion: ARRIF have a steady fixation effect on spinal fracture in three dimensional.
出处 《西南国防医药》 CAS 2000年第3期143-146,共4页 Medical Journal of National Defending Forces in Southwest China
关键词 内固定器 脊柱骨折 生物力学 internal fixator spinal fracture biomechanics
  • 相关文献

参考文献5

二级参考文献18

  • 1阮狄克 沈根标 等.三维立体摄像技术研究腰椎间盘切除对腰椎活动的影响[J].生物医学工程学杂志,1994,11:31-38.
  • 2过邦辅,生物力学杂志,1987年,2期,75页
  • 3徐莘香,骨伤科基础资料汇编,1987年
  • 4邹德成,中华外科杂志,1991年,29卷,476页
  • 5唐天驷,中华外科杂志,1989年,27卷,272页
  • 6Chang Kaowang,J Spinal Disorders,1988年,1卷,257页
  • 7邹德威,Spine,1993年,18卷,195页
  • 8邹德威,中华外科杂志,1992年,30卷,722页
  • 9邹德威,中华外科杂志,1991年,29卷,47页
  • 10唐天驷,中华外科杂志,1993年,31卷,411页

共引文献635

同被引文献26

  • 1杨惠林,唐天驷,朱国良,陈荣发,洪天禄,许立,郑祖根,王以进.钉杆角弓根内固定系统治疗胸腰椎骨折的研究[J].中华骨科杂志,1995,15(9):570-572. 被引量:91
  • 2邹德威,海涌,马华松.AF三维椎弓根螺钉系统的研制及其临床应用[J].中华外科杂志,1995,33(4):219-221. 被引量:417
  • 3杨惠林,唐天驷,朱国良,洪天禄,许立,陈荣发,郑祖根.胸腰椎骨折经椎弓根内固定治疗中的失误和并发症的分析[J].中华骨科杂志,1996,16(6):356-359. 被引量:155
  • 4侯树勋,史亚民,刘汝落,吴闻文.腰椎滑脱复位固定器的设计与应用[J].中华骨科杂志,1996,16(12):747-749. 被引量:52
  • 5Bohlmann A, Bergmann G, Graichen F, et al. Placing a bone graft more posteriorly may reduce the risk of pedicle screw breakage:analysis of an unexpected case of pedicle screw breakage. J Biomech,1998,31:763 -767.
  • 6Dick W. The "fixatuer interne" as a versatile implant for spine surgery. Spine, 1987,12:882-900.
  • 7Sairyo K,Scifert J,Goel VK,et al. Neurocentral synehondrosis fracture in immature spines associated with pedicle screw type fixation devices. J Spinal Disord, 1998,11:142-145.
  • 8Rohlmann A, Bergmarm G, Graichen F, et al. Placing a bone graft more posteriorly may reduce the risk of pedide screw brpAlcage: analysis of an unexpected case of pedide screw breakage. J Biomech,1998, 31 (8): 763.
  • 9Dick JC, Bourgeault CA. Notch sensitivity of titanium alloy, commercially pure titanium, and stainless steel spinal implants. Spine,2001, 26 (15): 1668.
  • 10Stambough JL, Sabri EH, Huston RL, et al. Effects of crosslinkage on fatigue life and failure modes of stainless steel posterior spinal constructs. J Spinal Disord, 1998, (3) : 221.

引证文献7

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部