期刊文献+

食品加工用具上淀粉残留现场快速检测方法研究 被引量:1

Study on rapid field detection of starch residues on food processing equipment
原文传递
导出
摘要 目的:建立棉签碘液法现场快速检测食品加工用具上淀粉残留的方法。方法:以棉签为反应载体,通过碘液浓度选择试验、直链和支链淀粉显色试验、干扰试验和现场应用试验,研究棉签涂布法检测淀粉的检测限和实际应用情况。结果:碘液最佳浓度为2.5 g/L,与淀粉反应显示蓝色或紫色,棉签涂布法对淀粉的检出限为12.5μg。结论:棉签碘液涂布法方法简便,结果直观,检出限低,是现场快速检测食品加工用具上淀粉残留的理想方法。 Objective:To study iodine on swab method for rapid field detection of starch residues on food processing equipment.Methods: Detection limit and practical application of iodine on swab method were analyzed by iodine concentration test,amylose and amylopectin color test,interference test and field application test.Results: The optimal concentration of iodine was 2.5 g/L.The reaction of iodine and starch showed blue or purple.Limit of detection of iodine on swab method for starch was 12.5 μg.Conclusion: The method of iodine on swab method is simple,visible with low limit of detection.It is an ideal method for rapid field detection of starch residues on food processing equipment.
出处 《中国卫生检验杂志》 北大核心 2012年第5期981-983,共3页 Chinese Journal of Health Laboratory Technology
基金 国家质检总局科技计划项目(2011QK335) 2010年度深圳市食品安全委员会项目(SZSAW2010007)
关键词 直链淀粉 支链淀粉 现场快速检测 Amylose Amylopectin Rapid field detection
  • 相关文献

参考文献6

二级参考文献43

共引文献44

同被引文献2

  • 1GBl4934-94食(饮)具消毒卫生标准[S].北京:中国标准出版社,1994.
  • 2GB4789.3-2010食品安全国家标准.食品微生物学检验大肠菌群计数.中华人民共和国卫生部[S].北京:中国标准出版社,2010.

引证文献1