摘要 含镍合金在口腔治疗中应用广泛,尤其在正畸学领域,包括金属托槽、弓丝、带环、推簧和结扎丝等,几乎伴随在正畸治疗的整个过程中。应用于人体的材料必须具有良好的生物安全性。近年来,随着人们健康意识的提高,口腔材料的腐蚀和其潜在的毒性作用已逐渐受到关注。本文将针对正畸治疗中含镍合金生物安全性的研究进展作一综述,具体包括镍离子的释放,含镍合金致敏性、细胞毒性、致癌性以及机体其他器官的不良反应等内容。 Nickel containing alloys have been widely used in the provision of various forms of dental care. Furthermore, these alloys are commonly used in orthodontic applications, such as brackets, arch wires, bands, springs and ligature wires. Nickel containing alloys are almost along with the whole process of orthodontic treatment. As materials used for human body, biosafety of dental material is now a fundamental requirement of successful clinical behavior in oral cavity. Nowadays, corrosion and the potential toxicity of nickel containing alloys has been taken seriously with the developing of health awareness. This article reviewed recent studies of the biosafety of nickel containing alloys, the variables included the release of nickel ion from alloys, the sensitization, cytotoxicity, the carcinogenecity and the adverse reactions to other organs of nickel containing alloys.
作者 李桦 胡敏
出处 《国际口腔医学杂志》 CAS 2012年第2期233-236,共4页 International Journal of Stomatology
关键词 含镍合金 正畸 生物安全性 不良反应 nickel containing alloys orthodontics biosafety adverse reaction
  • 相关文献

参考文献2

二级参考文献19

  • 1王革,程祥荣.阳极氧化对纯钛氧化膜影响的初步研究[J].中华口腔医学杂志,2001,36(6):30-33. 被引量:17
  • 2王小祥,毛志远,曹征旺,秦仁义,彭淑牖,江献川.TiNi形状记忆合金腐蚀及细胞毒性的研究[J].中国生物医学工程学报,1996,15(4):374-377. 被引量:26
  • 3曹宏梅,赖红伟,董树国,朱志国.微量元素镍概论[J].广东微量元素科学,2006,13(12):1-6. 被引量:22
  • 4Geis -Gerstorfer J, Weber H. Effect of potassium thiocyanate on corrosion behavior of non - precious metal dental alloys. Dtsch Zahnarztl Z, 1985, 40(2) :87 -91.
  • 5Rondelli G, Vicentini B. Localized corrosion behaviour in simulated human body fluids of commercial Ni - Ti orthodontic wires. Biomaterials, 1999, 20 ( 8 ) :785 - 792.
  • 6Huang HH. Variation in surface topography of different NiTi orthodontic archwires in various commercial fluoride- containing environments. Dent Mater, 2007, 23 ( 1 ) :24 - 33.
  • 7Li X, Wang J, Hart EH, et al. Influence of fluoride and chloride on corrosion behavior of Ni -Ti orthodontic wires. Acta Biomater, 2007, 3(5) :807 -815.
  • 8Walker MP, White RJ, Kula KS. Effect of fluoride prophylactic agents on the mechanical properties of nickel - titanium - based orthodontic wires. Am J Orthod Dentofacial Orthop,2005, 127(6) : 662 - 669.
  • 9Nakagawa M, Matsuya S, Ohta M. Effect of fluoride concentration and pH on the corrosion behavior of titanium for dental use. J Dent Res, 1999, 78:1568 - 1572.
  • 10Aziz-kerro M,Conroy KG,Fenelon AM,et al.Electrohemical studies on the stability and corrosion resistance of titanium-based implants materials[J].Biomaterials,2001,22(12):1531-1539.