期刊文献+

基于槽式悬臂梁结构的微质量传感器设计 被引量:3

Design and analysis of micro-mass sensor based on Ⅰ-shaped cross-section cantilever
在线阅读 下载PDF
导出
摘要 压电式微质量传感器的测试精度直接依赖于结构频率对质量变化的灵敏程度。本文利用对称槽型梁和压电薄膜组成的对称敏感结构,提出了一种提高传感器灵敏度的结构设计方法,并设计了一种高精度谐振式微质量传感器。建立了结构频率变化对吸附质量敏感性的分析模型,并研究了槽型截面参数、自振频率及振动模态对灵敏度的影响。与矩形截面结构进行了仿真与实验对比,结果表明,相同几何尺寸参数下,槽型截面悬臂梁的一阶自振频率为1 851Hz,矩形截面悬臂梁的一阶自振频率为1 610Hz,相应的传感器灵敏度则分别为3.12×104 Hz/g和1.5×104 Hz/g,前者是后者的2倍。该项设计为提高微质量传感器灵敏度提供了一种新思路。 As the sensitivity of a piezoelectric mass sensor directly depends on the structural frequency variation induced by the mass added. This paper proposes a structure designing method for improving the measuring sensitivity of the mass sensor by using a structure which consists of a symmetrical trough (I-shaped cross-section) cantilever and piezoelectric films. Then, we design and fabricate a novel piezoelectric resonance micro-mass sensor. Considering the influences of the section shape, natural frequency and the vibration mode on the sensitivity, an analytical model is established for analyzing the frequency variation caused by the micro particles. With the same geometric parameters, the simulation and experiments are performed for the sensors with the I-shaped cross-section cantilever and the rectangular section cantilever. It shows that the first order natural frequency of the I-shape cross-section cantilever is 1 851 Hz, and that of the rectangular section cantilever is 1 610 Hz. Moreover, corresponding sensor sensitivities are 3.12×104 and 1.5×104 Hz/g, respectively, and the former is twice of the latter. The method is feasible and effective for improving the measuring precision of mass sensors.
出处 《光学精密工程》 EI CAS CSCD 北大核心 2012年第1期102-108,共7页 Optics and Precision Engineering
基金 国家973重点基础研究发展计划资助项目(No.2011CB610304) 教育部博士学科点基金资助项目(No.20090041110023 No.20100041120019)
关键词 质量传感器 槽型悬臂梁 压电薄膜 灵敏度 mass sensor I-shaped cross-section cantilever piezoelectric film sensitivity
  • 相关文献

参考文献22

  • 1WARD M D, BUTTRY D A. In situ interfacial mass detection with piezoelectric transducers[J]. Science, 1990, 249: 1000-1007.
  • 2BURG T P, GODIN M, KNUDSEN S M, et al.. Weighing of biomeolecules, single cells and single nanoparitcles in fluid [J]. Nature, 2007, 446(2): 1066-1069.
  • 3SAKTI S P, ROSLER S, LUCKLUM R, et al.. Thick polystyrene-coated quartz crystal microbal- anee as a basis of a cost effective immunosensor [J]. Sens. Actuators A, 1999, 76(1-3): 98-102.
  • 4LIN Z, YIP C M, JOSHEPH I S, et al.. Opera- tion of an ultrasensitive 30 MHz quartz crystal mi- crobalanee in liquids [J]. Anal. Chem. ,1993, 65 (11) : 1546-1551.
  • 5VERISSIMO M I S, MANTAS P Q, SENOS A M R, et al.. Suitability of PZT ceramics for mass sen- sors versus widespread used quartz crystals[J]. Sensors and Actuators B, 2003, 95(1-3) : 25-31.
  • 6SHIH W Y, LI X, GU H, et al.. Simultaneous liquid viscosity and density determination using pie- zoelectric unimorph cantilevers[J].J. Appl. Phys. , 2001, 89(2): 1497-1505.
  • 7LI X, SHIH W Y, AKSAY I A, et al.. Electro-mechanical behavior of PZT-brass unimorphs [J]. J. Am. Ceram. Soc. , 1999, 82(7):1733-1740.
  • 8YIJW, SHIHWY, SHIHW H. Effect oflengt h, width, and mode on the mass detection sensitivi- ty of piezoelectric unimorph cantilevers [J]. J. Ap- pl. Phys. , 2002, 91(3)..1680-1686.
  • 9SHIH W Y, LI X, GU H, et al.. Simultaneous liquid viscosity and density determination with pie- zoelectric unimorph cantilevers [ J ]. J. Appl. Phys. , 2001, 89(2): 1497-1505.
  • 10SHEN Z, SHIH W Y, SHIH W H. Flexural vi- brations and resonance of piezoelectric cantilevers with a nonpiezoelectric extension [J]. IEEE Trans. Ultrason. Ferro. Freq. Control, 2007, 54 (10):2001-2010.

二级参考文献22

  • 1Ward M D, Ebersole R C. Piezoelectric specific binding assay with mass amplified reagents[P]. US patent: 5501986, 1996.
  • 2Bauer G, Pittner F, Schalkhammer T h. Metal nano-cluster biosensors[J]. Mikroehim Acta, 1999,131:107-114.
  • 3Maxwell D, Taylor M J, Nic S.Self-assembled nanoparticlr probes for recognition and detection of biomolcculcs[J]. J Am Chem Soc, 2002,124:9606-9612.
  • 4Safarik I, gafarikova M. Use of magnetic techniques for the isolation of cells[J]. J Claromatogr B, Biomed Sci Atrial. 1999. 722:33-53.
  • 5Richardson J, Hawkins P, Luxton R.The use of coated paramagnetic particles as a physical label in a magncto-immunoassay[J]. Bioscnsors and Bioelectronics, 2001,16:989-993.
  • 6Chemla Y R, Grossman H L, Poon Y,ct al. Ultrasensitive magnetic bioscnsors for homogeneous immunoassay[J]. Proc Nail Acad Sci USA, 2000, 97:14268-14272.
  • 7Gonzalez-Garcia M B,Fernandez-Sanchez C, Costa-Garcia A.Colloidal gold as an electrochemical label of streptavidin-biotin interaction[J].Biosensors and Bioelectronics, 2000, 15:315-321.
  • 8PSingh A K, Flouders A W, Volponi J V. Development of sensors for direct detection of organophosphates. Part I:immobilization, characterization and stabilization of acetylcholinesterase and organophosphate hydrolase on silica supports[J]. Biosensors and Bioelectronics, 1999, 14:703-713.
  • 9Xu X, Liu S, Ju H. A novel hydrogen peroxide sensor via the direct electrochemistry of horseradish peroxidase immobilized on colloidal gold modified screen-printed electrode[J]. SENSORS, 2003, 3:350-360.
  • 10Cui Y, Wei Q, Park H, Lieber C M. Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species[J]. SCIENCE, 2001,293:1289-1292.

共引文献31

同被引文献27

  • 1任杰,何永红,高志贤.压电生物传感器研究进展[J].生物技术通讯,2004,15(5):519-522. 被引量:10
  • 2方亮,肖锋,陶再南,汪立文,向井楠宏.用改良密度法精密测量熔融Ni-Ta二元合金的液态密度(英文)[J].稀有金属材料与工程,2005,34(4):521-525. 被引量:6
  • 3张娜,冯霞.光纤传感器在液体参量测量中的应用[J].中国激光,2006,33(1):67-71. 被引量:12
  • 4刘剑,李昕欣,金大重,刘民,王跃林,左国民,余海涛,包菡涵.高阶谐振模态的超高质量分辨硅微悬臂梁压阻传感器[J].Journal of Semiconductors,2006,27(8):1496-1502. 被引量:3
  • 5冼爱平,王连文.液态金属的物理性能[M].北京:科学出版社,2006:116.
  • 6BURG T P, GODIN M, KNUDSEN S M, et al. Weig- hing of biomeolecules, single cells and single nanoparit- cles in fluid[ J]. Nature,2007,446 ( 2 ) : 1066-1069.
  • 7YI J W, SHIH W Y, SHIH W H. Effect of length, width, and mode on the mass detection sensitivity of piezoelectric unimorph cantilevers [ J ]. Journal of Applied Physics, 2002,91 (3) : 1680-1686.
  • 8SHEN Z, SHIH W Y, SHIH, W H. Mass detection sensi- tivity of piezoelectric cantilevers with a nonpiezoeleetric extension [ J ]. Review of Scientific Instruments, 2006, 77(6) :065101.
  • 9SHEN Z,SHIH W Y,SHIH W H. Flexural vibrations and resonance of piezoelectric cantilevers with a nonpiezoelee- trie extension[ J ]. IEEE Transactions on Ultrasonics, Fer- roeleetries, and Frequency Control, 2007, 54 ( 10 : 2001-2010.
  • 10EKINCI K L, HUANG X M H, ROUKES M L. Ultrasensi- tire nanoeleetromechanical mass detection [ J ]. Applied Physics Letters, 2004,84 (22) :4469-4471.

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部