摘要 将奇异值分解和主成分回归相结合,首次用于药物的含量测定,采用紫外分光光度法同时测定克感敏片中的非那西丁、氨基比林和咖啡因的含量.其结果明显优于最小二乘法. A method of the combination of singular value decomposition and principal component regression has been developed to determine simultaneously phenacetin,aminopyrine and caffeine in the compound chlorphenamine tablet.The results are evidently superior to that of the ordinary least square method.
出处 《沈阳药科大学学报》 CAS CSCD 1999年第3期215-216,共2页 Journal of Shenyang Pharmaceutical University
关键词 奇异值分解 主成分回归 克感敏片 singular value decomposition principal component regression compound chlorphenamine tablet phenacetin aminopyrine caffeine
  • 相关文献

参考文献7

二级参考文献1

  • 1任英,佟玉兰.稀土高氯酸溶液导数光谱的研究及其在分析中的应用——Ⅲ.导数分光光度法测定混合稀土中的镨、钕、钐、铕、镝、钬、铒、铥[J]应用化学,1985(03).

共引文献21

同被引文献12

  • 1梁毅雄,龚卫国,潘英俊,李伟红,刘嘉敏,张红梅.基于奇异值分解的人脸识别方法[J].光学精密工程,2004,12(5):543-549. 被引量:40
  • 2陈明,丁云川,李静,尹帆,刘超,王庆慧,郑家亮,朱隶军,王跃.舒张早期左心室流入血流色阶差的二维彩色多普勒超声研究[J].中华超声影像学杂志,2006,15(5):340-343. 被引量:4
  • 3Tanaka M,Sakamoto T,Sugawara S,et al.Blood flow structure and dynamics,and ejection mechanism in the left ventricle:analysis using echo-dynaraography.J Cardiol,2008,52:86-101.
  • 4Claessens TE,De Sutter J,Vanhercke D,et al.New echocardiographic applications for assessing global left ventricular diastolic function.Ultrasound Med Biol.2007,33:823-841.
  • 5Mey SD,Sutter JD,Vierendeels J,et al.Diastolic filling and pressure imaging:taking advantage of the information in a clour M-mode Doppler image.Eur J Echocardiogr,2001,2:219-233.
  • 6Greenberg NL,Vandervoort PM,Firstenberg MS,et al.Estimation of diastolic intraventricular pressure gradients by Doppler M-mode echocardiography.Am J Physiol Heart Circ Physiol,2001,280:H2507-H2515.
  • 7Nakamura M,Wada S,Mikami T,et al.Computational study on the evolution of an intraventricular vortical flow during early diastole for the interpretation of color M-mode Doppler echocardiograms.Biomech Model Mechanobiol,2003,2:59-72.
  • 8Kheradvar A,Gharib M.On mitral valve dynamics and its connection to early diastolic flow.Ann Biomed Eng,2009,37:1-13.
  • 9Shiota T.Automated cardiac flow measurement by digital colour Doppler echocardiography.Heart,2002,88:278-282.
  • 10National Drug Specification Promulgated by SDA, Vol 12 (国家药品监督管理局《国家药品标准》第十二册).2002.31