期刊文献+

近红外光谱技术对胶质瘤大鼠优化散射系数的研究 被引量:1

Measurement of reduced scattering coefficient of C6-glioma rats by near infrared spectroscopy technique
暂未订购
导出
摘要 目的探讨应用近红外光谱技术测量C6荷瘤大鼠脑胶质瘤优化散射系数的特点。方法选取40只SD大鼠随机分为实验组和对照组,每组20只。将培养的C6细胞立体定向接种于SD大鼠的尾状核,MR I检查肿瘤生长至直径0.5~1.0 cm时作为实验组,正常大鼠作为对照组。利用稳态光纤光谱仪的微创光学探头测量各组的优化散射系数。结果胶质瘤组的优化散射系数低于对照组(P<0.05)。结论近红外光谱技术可以应用于胶质瘤的检测,其中优化散射系数是检测脑胶质瘤的良好指标。 Objective To observe the characteristics of reduced scattering coefficient measurement of living C6-glioma rats by near infrared spectroscopy technique.Methods Forty SD rats were randomly divided into 2 groups,C6-glioma group and control group.C6 cells were injected in SD rat caudate nucleus by means of subculture of stereotactic inoculation.When the glioma had grown to 0.5~1.0 cm in diameter as experimental group by MRI detection.A specific designed fiber optical spectrum system was applied to measure the optical parameters(reduced scattering coefficient) in 20 C6-glioma rats compared to control group.Results Reduced scattering coefficient in experimental group was lower than that in control group(P0.05).Conclusion The near infrared spectroscopy technique can be applied to detect the glioma,and reduced scattering coefficient can be used for the glioma quantification.
出处 《山东医药》 CAS 北大核心 2011年第20期17-19,共3页 Shandong Medical Journal
基金 国家自然科学基金资助项目(30671997)
关键词 近红外光谱 胶质瘤 优化散射系数 near infrared spectroscopy technique glioma reduced scattering coefficient
  • 相关文献

参考文献6

  • 1钱志余,顾月清,刘汉莉.实时在位测定大鼠脑组织优化散射系数(μ's)的技术研究[J].中国医学物理学杂志,2005,22(2):463-465. 被引量:12
  • 2钱志余,陈仁文,顾月清,Cole A.Giller,刘汉莉.生物组织光学参数:优化散射系数(μ′_s)的实时在位测定[J].南京航空航天大学学报,2004,36(3):369-372. 被引量:14
  • 3P. Pasdois,C. Deveaud,P. Voisin,V. Bouchaud,M. Rigoulet,B. Beauvoit.Contribution of the Phosphorylable Complex I in the Growth Phase-Dependent Respiration of C6 Glioma Cells in Vitro[J]. Journal of Bioenergetics and Biomembranes . 2003 (5)
  • 4Amharref N,Beljebbar A,Dukic S,et al.Brain tissue characterisa-tion by infrared imaging in a rat glioma model. Biochimica et Biophysica Acta . 2006
  • 5Krafft C,Sobottka SB,Schackert G,et al.Near infrared Ramanspectroscopic mapping of native brain tissue and intracranial tumors. The Analyst . 2005
  • 6Tuettenberg J,Friedel C,Vajkoczy P.Angiogenesis in malignant glioma—a target for antitumor therapy?. Critical Reviews in Oncology Hematology . 2006

二级参考文献18

  • 1L.Reynolds, C.Johnson and A.Ishimaru, Diffuse reflectance from a finite blood medium: applications to the modeling of fiber optical catheters[J]. Appl. Opt., 1976,15:2059-2067.
  • 2R.A.J. Groenhuis, H.A. Ferwerda, and J.J. Ten Bosch, Scattering and absorption of turbid materials determined from reflection measurements. 1:theory[J]. Appl. Opt., 1983,22:2456-2462.
  • 3J.M. Steinake and A.P. shepherd, Diffusion model of the optical absorbance of whole blood[J]. J.Opt. Soc. Am., 1998,A(5):813-822.
  • 4J.J.M. Schmitt, G.X. Zhou, and E.C. Walker, Multilayer model of photon diffusion in skin[J]. J.Opt. Soc. Am., 1990,A(7):2141-2153.
  • 5W.F. Cheong, S.A. Prabl, A.J. Welch, A review of the optical properties of biological tissue[J]. IEEE J.Quantum Electron., 1990,26:2166-2185.
  • 6钱志余.[D].南京航空航天大学,2003.50-64.
  • 7Zhiyu Qian, Sunder S. Victor, Yueqing Gu, etc. "Look-Ahead Distance" of a fiber probe used to assist neurosurgery:Phantom and Monte Carlo study[J]. OPTICS EXPRESS, 2003,11(16):1844-1856.
  • 8S. J. Matcher, M. Cope, D. T. Delpy, In vivo measurements of the wavelength dependence of tissue-scattering coefficients between 760 nm and 900 nm measured with time-resolved spectroscopy [J].Appl. Opt., 1997,36:386-396.
  • 9Cheong W F, Prahl S A, Welch A J. A review of the optical properties of biological tissues[J]. IEEE J Quantum Electron, 1990, 26:2166~2185.
  • 10Reynolds L, Johnson C, Ishimaru A. Diffuse ref-lectance from a finite blood medium: applications to the modeling of fiber optical catheters[J]. Appl Opt,1976,15: 2059~2067.

共引文献18

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部