摘要 目的探讨新的近红外光谱技术来测量C6胶质瘤荷瘤鼠脑局部血氧饱和度(SO2)的特点。方法利用光学探头微创测量30只C6荷瘤鼠瘤体局部SO2,并与对侧脑组织SO2进行比较。结果瘤体内SO2较正常脑组织SO2低,两者差异有统计学意义(P<0.05);有坏死或出血个体SO2曲线出现明显低峰。结论通过微创光学探头可以测量胶质瘤内SO2。 Objective To measure local cerebral blood oxygen saturation in C6 glioma rats in vivo by new near infrared spectroscopy (NIRS). Methods 30 C6 glioma-bearing rats were measured mini-invasively by a optic fiber probe revealing SO2. Intratumoural SO2 ( tSO2 ) was compared to normal cerebral tissue SO2. Results The mean SO2 of intratumoural tissue was(55. 1 ± 4.7)%,and the mean SO2 of normal tissue was (60.7 ± 2.5)% in contralateral cerebral tissue, respeetively. The difference is significant, Conclusions Measurement of glioma in vivo by NIRS is feasible.
出处 《临床神经外科杂志》 CAS 2007年第4期145-147,共3页 Journal of Clinical Neurosurgery
基金 国家自然科学基金资助(30671997)
关键词 C6脑胶质瘤 血氧饱和度(SO2) 近红外光谱(NIRS) C6 glioma saturation of blood oxygen ( SO2 ) near infrared spectrometer (NIRS)
  • 相关文献

参考文献10

  • 1[1]Harrigan M R.Angiogenic factors in the central nervous system[J].Neurosurgery,2003,53:639.
  • 2[2]Pasdois P,Deveaud C,Voisin P,et al.Contribution of the Phosphorylable Complex I in the Growth Phase-Dependent Respiration of C6 Glioma Cells in Vitro[J].Journal of Bioenergetics and Biomembranes,2003,35:439.
  • 3[3]Bernsen H J,Rijken P F,Hagemeier N E,et al.A Quantitative Analysis of Vascularization and Perfusion of Human Glioma Xenografts at Different Implantation Sites[J].Microvascular Research,1999,57:244.
  • 4[4]Qian Z Y,Victor S S,Gu Y Q,et al."Look-Ahead Distance" of a fiber probe used to assist neurosurgery:Phantom and Monte Carlo study[J].Optics Express Vol.No.16,11 August 2003,11,1844.
  • 5[5]Johns M,Giller C A,German D C,et al.Determination of reduced scattering coefficient of biological tissue from a needle-like probe[J].Optics Express 2005,13:4828.
  • 6[6]Tuettenberg J,Friedel C,Vajkoczy P.Angiogenesis in malignant glioma-A target for antitumor therapy[J].Critical Reviews in Oncology/Hematology,2006,59:181.
  • 7[7]Jobsis J J.Noninvasive,infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters[J].Science,1977,198:1264.
  • 8[8]Heikki Minn.PET and SPECT in low-grade glioma[J].European Journal of Radiology,2005,56:171.
  • 9[9]eun S S,Kim M C,Kim B S,et al.Assessment of malignancy in gliomas by 3T 1H MR spectroscopy[J].Journal of Clinical Imaging,2005,29:10.
  • 10[10]Asgari S,Rohrborn H J,Engelhorn T,et al.Intra-operative characterization of gliomas by near-infrared spectroscopy:possible association with prognosis[J].Acta Neurochir,2003,145:453.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部