期刊文献+

空气源热泵除霜问题研究现状与展望 被引量:25

Current Situation and Development Prospect of Air Source Heat Pump Defrosting Research
在线阅读 下载PDF
导出
摘要 从除霜方式和除霜系统优化、霜层形成机理、抑制结霜技术与结霜/除霜工况下机组的动态特性等4个方面对空气源热泵除霜问题的研究现状进行了评述,提出存在的问题并展望了今后研究的发展。 Due to the low temperature and high humidity outdoors in winter,frost will form and accumulate undesirably on the surface of outdoor heat exchanger,which will degrade the performance of air source heat pump(ASHP).The research on air source heat pump defrosting at home and abroad was reviewed from four aspects: optimization of defrosting system,mechanism?of frost formation,measures to retard frost and dynamic characteristics of system under frosting/defrosting conditions.The development prospect of ASHP was also carried out.
机构地区 中南大学
出处 《流体机械》 CSCD 北大核心 2011年第4期75-79,共5页 Fluid Machinery
关键词 空气源热泵 结霜 除霜 air source heat pump frost defrost
  • 相关文献

参考文献36

  • 1Kuwahara E, Kawamura T, Tamazaki M. Shortening the defrost time on a heat pump air conditioner[ J ].ASHRAE Trans, 1986,92 (2A) :20-29.
  • 2Nutter D W, O' Neal D L, Payne W V. Impact of the suction line accumulator on the frost/defrost performance of an air - source heat pump with a scroll compressor [ J ]. ASHRAE Trans, 1996,102 ( 1 ) : 689- 698.
  • 3O' Neal D L, Peterson K, Anand N K. Effect of short - tube Orifice sizeon the performance of an air source heat pump during the reverse - cycle defrost [ J ]. Int. J. Refrigeration, 1991,14 (1) : 52-57.
  • 4Payne V, O' Neal D L. Defrost cycle performance for an air- source heat pump with a scroll and a reciprocatingcompressor [J]. Int. J. Refrigeration, 1995, 18 (2) : 107-112.
  • 5Yanjun Ding, Guoyuan Ma, Qinhu Chai,et al. Experiment Investigation of reverse cycle defrosting methods on air heat pump with TXV as the throtde regulator [J]. Int. J. Refrigeration, 2004, 27(6) : 671-678.
  • 6Huang Dong, Yuan Xiuling, Zhang Xingqun. Effects of fan- starting methods on the reverse -cycle defrost performance of an air - to - water heat pump [ J ]. Int. J. Refrigeration, 2004, 27 (8) : 869-875.
  • 7董云达,付兰.空气源热泵机组除霜性能试验研究[J].制冷与空调,2007,7(2):68-71. 被引量:4
  • 8Wang Zhiyi, Wang Xinmin, Dang Zhiming. Defrost improvement by heat pump refrigerant charge compensating [J].Applied Energy. 2008,85(11) : 1050- 1059.
  • 9石文星,李先庭,邵双全.房间空调器热气旁通法除霜分析及实验研究[J].制冷学报,2000,21(2):29-35. 被引量:82
  • 10Ju - Suk Byun, Jinho Lee, Chang - Duk Jeon. Frost retardation of an air - source heat pump by the hot gas bypass method [ J]. Int. J. Refrigeration. 2008, 31(2) : 328-334.

二级参考文献63

共引文献201

同被引文献246

引证文献25

二级引证文献95

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部