基于在十二烷基硫酸钠存在下的弱碱性介质中Fe(Ⅲ)对H_2O_2氧化2,4-二氯苯酚(2,4-DCP)与4-氨基安替比林(4-AAP)偶联显色反应的催化作用,建立了检出限为7.90μg/L.线性范围为0~1.25mg/L的新催化光度分析法.方法用于血红细胞中铁的测定,相对标准偏差与回收率分别为2.6%与98.8%~101%,结果满意.
The catalytic coupling reaction of 2,4-dichlorophenol and 4-amino antipyrine with hydrogenperoxide by iron(Ⅲ) in a weak base medium was studied and its optimum conditions were established .The absorbance of the red product was measured at 502 nm with a detection hrnit of 7.9μg/L. The linearrange of this method was 0~1.25 mg/L and the relative standard deviation was 2.6%. The proposedmethod was used to determine trace iron in erythrocyte with satisfactory results.