兆瓦级风电机组抗台风塔架设计的初步研究

Pilot study on anti-typhoon of tower design
在线阅读 下载PDF
导出
摘要 根据某风电场台风的特点确定风机设计等级,在此基础上通过对塔架基本尺寸的预假设并建立基本物理模型,基于有限元法并根据风电设备的设计规范对抗台风风力发电机组塔架的主体塔筒进行了初步分析,主要包括塔架的低级频率和极限强度计算。通过对该风电机组初步设计中的塔架的基本设计工作初步确定该的塔架的固有频率和极限强度均满足风电机组的设计规范要求。然而建议在对抗台风风力发电机组塔架详细设计阶段必须进行进一步优化设计在强调足够的情况下减小尺寸,降低制造和运输成本。 According to a site wind condition,the turbine was classified.Assumption on the dimensions,the model of the turbine was constructed.Primary analysis on Anti-typhoon tower was made with Finite element method,including low class frequency and extreme strength.Some dependent conclusions and suggestions on anti-typhoon tower design were drawn that the frequency and extreme strength meet the design specification of turbine standards.Some suggestions which the tower dimensions had to be optimized in the details design phases to decrease the costs of manufacturing and transportation was made.
出处 《机械设计与制造》 北大核心 2011年第2期34-36,共3页 Machinery Design & Manufacture
关键词 塔架 有限元分析 抗台风 Tower Fea Anti-typhoon
  • 相关文献

参考文献5

  • 1IEC61400-1 (2005)[ S],2005.
  • 2Guideline for the Certification of Wind Turbines Edition 2003 with Suppl 2004.
  • 3Chii-Rong Yang, Yuang-Cherng Chiou,Rong-Tsong Lee. Tribological Be- havior of reciprocating friction drive system under lubricated contact[J]. Tri- bology International, 1999,32:443-453.
  • 4Ayad.S.S Numerical study of the performance of tornado-type wind energy systems[J] J.Energy:(United states) 72,1983.
  • 5Hsu.Ch.-T.Tornado type wind turbines [P] US4452562,1983(5 ).