介绍了国华沧东发电有限公司660MW超临界四号机组甩负荷试验的主要条件、措施及过程,对试验结果进行了分析计算。同时制定科学的安全措施及操作程序,实践表明,直流锅炉甩负荷试验后完全可以做到参数可控、稳定燃烧,为机组迅速并网创造条件。
This paper presents the main conditions,measures and procedures of load rejection test of No.4 660MW supercritical unit of Guohua Cangdong Power Generation Co.,Ltd.,analyzes and calculates the test results.Meanwhile,it suggestes and formulates a scientific safety precautions and operating procedures.The parameter control and stable combustion operation could be properly achieved after the load rejection test for once-through boiler,and be easy for the unit to be synchronized rapidly.
出处
《热力透平》
2010年第4期278-281,共4页
Thermal Turbine