摘要 对混合管束滑油冷却器和光管滑油冷却器进行对比试验研究,发现当滑油体积流量相同时,前者单位体积换热量较高,压降较小,换热能力强,综合性能优越,表明在同样换热量条件下可以使冷却器小型化。 A lot of comparison experimental research has been done to the lubricating-oil cooler with mixing integral pin-fin tubes and plain tubes.It is discovered that the mixing integral pin-fin tubes heat transfer capacity in unit volume is higher,pressure drop is lower,and the very strong heat transfer ability than plain tubes when oil volume flow rate is at constant value.The results show the performance of lubricating-oil cooler with mixing integral pin-fin tubes and plain tubes is superiority.So this can made lubricating-oil cooler miniaturize in the same Heat changing condition.
出处 《核科学与工程》 CAS CSCD 北大核心 2010年第2期155-159,共5页 Nuclear Science and Engineering
基金 黑龙江省教育厅基金资助项目(11541320)
关键词 冷油器 双流程 整体针翅管 混合管束 强化换热 oil cooler double-flow integral pin-fin tube tubes mixed bundle heat transfer enhancement