川丁特罗与人血浆蛋白结合率的测定 被引量:3

Determination of human plasma protein binding rate of trantinterol
原文传递
导出
摘要 目的建立测定川丁特罗与人血浆蛋白结合率的方法。方法采用平衡透析法对川丁特罗与人血浆蛋白结合率进行超高效液相色谱-串联质谱法(UPLC-MS/MS)测定。结果川丁特罗在低、中、高3个浓度下的人血浆蛋白结合率为(33±s 6)%,(29±9)%和(29±7)%。结论本方法简单、快速、灵敏,能满足分析要求。川丁特罗与人血浆蛋白结合程度不高,不存在浓度依赖性。 AIM To establish a method for the determination of the human plasma protein binding rate of trantinterol. METHODS Equilibrium dialysis was utilized for the determination of the plasma protein binding rate of trantinterol with ultra performance liquid chromatography-electrospray tandem mass spectrometry (UPLC- MS/MS). RESULTS The plasma protein binding rates of trantinterol at low, middle and high concentrations were (33 ± s 6) %, (29 ± 9) % and (29 ± 7) % respectively. CONCLUSION The method is simple, fast, sensitive and satisfied for the requirements. The binding power of trantinterol to human plasma is low without concentration dependence suggesting safety in clinical application.
出处 《中国新药与临床杂志》 CAS CSCD 北大核心 2010年第7期524-528,共5页 Chinese Journal of New Drugs and Clinical Remedies
基金 2008年辽宁省高等学校科研项目计划(2008716)
关键词 川丁特罗 血浆 蛋白质鲒合 平衡透析法 trantinterol plasma protein binding equilibrium dialysis