摘要
目的:采用HPLC测定心宁胶囊中葛根素含量,以控制该制剂的质量。方法:用十八烷基键合硅胶柱分离葛根素,以甲醇水磷酸(280∶720∶0.15)为流动相,检测波长250nm。结果:葛根素峰与其它组分峰的分离度大于1,理论塔板数以葛根素峰计算为8310;线性范围0.2~2μg(r=0.9999);平均回收率99.4%,RSD=2.47%(n=5)。结论:本法简便、快速。
OBJECTIVE:To domminate the quality of Xinning capsule,the contents of Puerarin in Xinning capsule was determined by HPLC.METHOD:Puerarin was separated on Spherisorb C 18 column and detected at 250nm,by using methanol water phosphoric acid (280∶720∶0.15)as mobile phase.RESULTS:The resolution was greater than 1. The number of theoretical plates calculaled for Puerarin peak was 8310;The standard curve was linear over the range of 0.2~2μg with the correllation coefficient 0.9999.The average recovery was 99.4% with RSD =2.47%( n =7).CONCLUSION:The method is simple and fast,and can be used for quantitative analysis of Xinning capsule.