摘要
建立了快速测定鱼肉中氯霉素残留的高效液相色谱-串联质谱方法。采用乙酸乙酯提取样品中的氯霉素残留,浓缩提取物用正己烷脱脂净化后,用反相液相色谱分离,以液相色谱-串联质谱仪测定,外标法定量。该法对氯霉素的线性范围为0.04~1.0μg/kg,相关系数R2=0.9999,在0.10、0.20、0.40μg/kg3个添加水平范围内的回收率为91.0%~100.1%,相对标准偏差为2.6%~4.1%,检测限为0.01μg/kg,定量限为0.02μg/kg。
An High-performance liquid chromatographic method with tandem mass spectrometry (HPLC-MS/MS) was developed for the determination of Chloramphenicol (CAP) residue in fish.The CAP residue was extracted by ethyl acetate.Concentrated extracts were redissolved in 1 mL dissolving solution and defatted by hexane.The solution was separated on a RP-HPLC column and detected by HPLC-MS/MS with positive electrospray ionization(ESI-) in multiple reaction monitoring(MRM) mode.Quantitation was carried out using an external standard method.The standard curve for CAP was linear over the concentration range of 0.04-1.0 tzg/kg with correlation coefficients (R2) of 0.9999. The recoveries of CAP from fish samples spiked with the concentration levels at 0.10, 0.20, 0.40μg/kg were range of 91.0%-100.1%. The relative standard deviations were 2.6%-4.1%. The limit of detection for the method was 0.01 μg/kg. The limit of quantification for the method was 0.02μg/kg. Key words: High performance liquid chromatography-tandem mass speetrometry(HPLC-MS/MS); Chloramphenicol; Residue; Fish