期刊文献+

600MW发电机组设备事故及维修探讨

Discussion on Equipment Fault and Maintenance of 600 MW Generator Units
原文传递
导出
摘要 目前,大部分并网运行的600 MW火力发电机组已进入或接近A级检修周期,面临设备大修的问题。对600 MW火力发电机组在运行、检修中发现的一些如发电机绝缘引水管缺陷、发电机引线烧毁等共性问题进行了分析、探讨,并提出了相应的解决措施,希望有助于提高600 MW机组的检修质量和其制造、运行管理水平。 Up to now,most of the 600 MW thermal generator units under operation in China have entered or are approaching the period of class A maintenance,needing general overhaul.The paper makes an analysis of some common problems encountered in operation and maintenance of 600 MW thermal generator units,such as defects of insulated water pipes of generators,burning of generator lead wires,and proposes some relevant measures,which is expected to be helpful for upgrading the overhaul quality,and the manufacture level as well as the operation management levels of 600 MW thermal generator units.
作者 孙国彬 朱超
机构地区 大唐淮北发电厂
出处 《电力建设》 2010年第6期119-121,共3页 Electric Power Construction
关键词 600MW机组 机组检修 绝缘监督 线圈震动 耐压试验 接地故障 b 600 MW generator units generator unitoverhaul insulating monitoring coil vibration withstand voltagetest ground fault
  • 相关文献

参考文献2

二级参考文献31

共引文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部