期刊文献+

G-M计数管用于环境γ辐射监测 被引量:9

MONITORING FOR ENVIRONMENTAL γ RADIATION USING G M COUNTER
在线阅读 下载PDF
导出
摘要 为测量环境γ辐射周围剂量当量,对G-M计数管的自身本底和能量响应特性进行了实验研究。采用铅、锡两种金属材料做为过滤器改变计数管的能量响应,为拓宽仪表量程采用两种尺寸计数管。两种计数管在60keV至662keV范围内,H*(10)/X随能量变化与ICRU47号报告结果最大偏离分别为-23%和+24%,仪表量程为10nSv·h-1~10mSv·h-1,探测下限可达到40nSv·h-1。 For measuring H *(10) from environmental γ radiation, the background and energy response of G M counter was studied. The energy response can be improved by a filter consisted of Sn and Pb. In order to extend the measuring range, we used two counters with different size. For two improved G M counters, the maximum deviations of H *(10) varing as energy of γ radiation from the results given by ICRU 47 are -23% and +24%, respectively between 60 keV and 662 keV. The instrument range is 10 nSv·h -1 ~10 mSv·h -1 , and the lower limit of detection is in the order of 40 nSv·h -1 . (
出处 《辐射防护》 CAS CSCD 北大核心 1999年第2期132-134,共3页 Radiation Protection
关键词 G-M计数管 能量响应 环境监测 γ辐射监测 G M Counter, Energy Response, Environmental Monitoring)
  • 相关文献

参考文献5

二级参考文献13

  • 1潘自强,陈竹舟,王志波,谢建伦.中国核工业三十年辐射环境质量评价[J].辐射防护,1989,9(4):241-247. 被引量:21
  • 2卜万成,毕克娜,宣义仁.环境放射性连续监测[J].辐射防护通讯,1993(3):14-20. 被引量:5
  • 3岳清宇,肖雪夫,金花.核设施环境连续监测[J].原子能科学技术,1997,31(1):35-43. 被引量:4
  • 4Dan I M,IEEE Trans NS,1976年,23卷,1期,710页
  • 5肖雪夫,原子能科学技术,1996年,31卷,1期,44页
  • 6刘建,第7届全国核电子学与核探测技术学术年会论文集.3,1994年
  • 7金华晋,中国原子能科学研究院报告,1993年
  • 8支冲骥,秦山核电厂外围环境监督监测结果年报,1993年,23页
  • 9团体著者,辐射防护,1992年,12卷,2期,96页
  • 10岳清宇,辐射防护,1986年,6卷,1期,29页