期刊文献+

1000MW机组低负荷凝结水溶氧超标的治理 被引量:1

Treatment of overproof dissolved oxygen in condensate of 1000 MW unit at low-load operation
在线阅读 下载PDF
导出
摘要 介绍了1 000MW机组在低负荷状态下存在着凝结水溶解氧的超标问题,结合机组实际,详细论述了排查凝结水溶解氧超标的整个过程,对超标原因进行了分析,制订了相应的措施,彻底解决了凝结水溶解氧的超标问题,为同类型机组解决同类问题提供了借鉴方法。 The dissolved oxygen in the condensing water of 1 000 MW unit at low-load operation exceeded the standard value.Combining with the practical status of the unit,the whole check-up process of overproof dissolved oxygen in condensate was described in detail.The reasons caused the standard value exceeded were analyzed,the proper measures were worked out,and the problem of overproof dissolved oxygen in condensate was solved thoroughly.This provides reference for solving the similar problems of the similar units.
出处 《华电技术》 CAS 2009年第11期47-49,共3页 HUADIAN TECHNOLOGY
关键词 超超临界机组 凝结水溶氧 超标原因 解决措施 ultra-supercritical unit dissolved oxygen in condensate the reason caused standard value exceeded solving measure
  • 相关文献

参考文献1

  • 1勒智平.电厂汽轮机原理及系统[M].2版.北京:中国电力出版社,2006.